6.3 CLAMP ON AC/DC SENSOR Specifications
117
1
2
3
4
5
6
7
8
9
10
S
p
eci
ficat
io
ns
Dimensions
Approx. 53W X 129H X 18D mm
(Approx. 2.09"W X 5.08"H X 0.71"D)
Mass
Approx. 230 g (8.1 oz.)
Cable length
Approx. 2 m (6.5 feet)
Accessory
Instruction manual....................................................... 1
Applying standards
Safety
EN61010 Type A current sensor
Measurement categories III
(Anticipated Transient Overvoltage: 6000 V)
Pollution Degree 2
EMC
EN61326
Continuous Input
Range
DC
to 66 Hz
66 to 500 Hz
0 to 80 A
± 1.0%rdg. ± 0.5 mV
± 1.0%rdg. ± 0.5 mV
± 2.0%rdg. ± 0.5 mV
80 to 100 A
± 2.5%rdg. ± 0.5 mV
Peak Input
Range
DC
to 66 Hz
66 to 500 Hz
0 to 110 A
± 1.0%rdg. ± 2 mV
± 1.0%rdg. ± 2 mV
± 2.0%rdg. ± 2 mV
110 to 150 A
± 2.5%rdg. ± 2 mV
Frequency (Hz)
100 k
10 k
1 k
100
10
1
-30
-25
-20
-15
-10
GA
IN
(
d
B)
5
0
-5
Model 9691 Frequency Characteristics
Frequency (Hz)
10 k
1 k
100
10
60
80
100
120
100 k
40
20
0
Model 9691 Derating According to Frequency
Inp
u
t cur
re
n
t
(A
)