4
―――――――――――――――――――――――――――――――――――――――
Chapter 2 Specifications
―――――――――――――――――――――――――――――――――――
Rated current
(Power meter) 15 Arms (continuous rating)
Crest factor
(Power meter) Power, current: 2 max at maximum
display or 30 A peak (lower value)
Voltage: 500 V peak value max
Output terminals
(Power meter) 2 VDC/f.s. 2 VDC output for 200 V
input in voltage function only.
(Integrator) Hi: 5V, Lo: 0 V CMOS level
External control
terminal
(Integrator) OFF: Open (or Hi: 5 V)
ON: Closed (or Lo: 0V)
Dielectric strength
AC 2.4 kV/1 min (between input terminals and case)
Power supply
100, 120, 220, 240 VAC
±
15%, 50/60 Hz
Rated power
Approx. 3.5 W
Effect of power supply
voltage
Specified accuracy satisfied within above specified
line voltage ranges.
Backup power
R6P manganese batteries
×
3 (supplies more than 100
hours backup capability)
Dimensions
Approx. 218 (W)
×
85 (H)
×
240 (D) mm
(excluding protrusions)
Mass
2.6 kg
Accessories
Power cord 1
Instruction Manual 1
Options
3171 DIGITAL PRINTER
9084 CARRYING CASE
9149 CARRYING CASE
Summary of Contents for 3181-01