background image

mounting instructions

Family: 120V Series Spot Light      Item No. 55000 BZ 

1.

 Make sure electrical supply is off at the circuit breaker before starting

luminaire installation or servicing.

2.

 Thread luminaire onto junction box or other mounting device (not provided)

until it is at desired direction using thread sealant. Tighten jam nut 

(A)

 provided

to ensure the luminaire is locked to adjusted position - see 

Drawing 1/Diagram 2

.

 

3.

 Attach luminaire leads to line in leads observing polarity, black to black, white to 

white and green to ground using silicone filled safety connectors provided.

4.

 Attach junction box cover with luminaire to junction box (not provided) .

Make sure not to pinch wires that may be sandwiched between cover and box.

5.

 Coat exposed luminaire threads with thread sealant to keep moisture from entering 

junction box or other mounting device.

6.

 To adjust luminaire aiming angle, untighten screw 

(B)

 found on adjustable knuckle 

(1)

 - see 

Drawing 1/Diagram 2

. Do not disengage totally. 

Hold luminaire at selected angle and tighten adjustable knuckle screw firmly.

NOTE: If an R-20 lamp is used with this luminaire, lensed shroud must be installed
at all times.

7.

 This luminaire is provided with a shroud 

(2)

 as shown in the instruction

sheet. To install shroud loosen set screws 

(C)

. Turn shroud 

(2)

 in a circular motion

while shroud slides into housing 

(4)

 Do not push straight into the housing to

prevent O-Ring 

(D)

 from slipping out of its groove. The shrouds may be used in

combination with one another.

8.

 Coat all exposed screws with silicone grease.

9.

 Please refer to front of this sheet to install lamp.

Drawing 1 - Fixture Mounting

WARNING: TO REDUCE THE 
RISK OF FIRE, OR INJURY 
TO PERSONS:

1.

 Turn off/unplug and allow

to cool before replacing lamp.

2.

 Lamps get hot quickly! 

Contact only switch/plug 
when turning on.

3.

 Do not touch hot lens, 

guard or enclosure.

4.

 Keep lamp away from 

material that may burn.

5.

 Do not operate luminaire

fitting with a missing 
or damaged cover.

(Diagram  1)

(Diagram  2)

2

C

D

B

A

1

4