background image

METAL
TEMPLATE
W/ BOLTS

ELECTRICAL
SUPPLY 
WIRE

BOLT PATTERN

  120
DEGREES 

4-1/2”

9” bolt circle

use metal template provided with pole

check local building codes prior to installation

POST
BASE

CAP
NUT

HEX NUTS CAN BE 
ADJUSTED TO 
INSURE
POLE IS PLUM

4.  MOUNTING LAMP POST TO FOOTING

1.  Thread hex nuts onto anchor bolts and adjust to that the tops of the hex nuts are 1-1/4” above the 
footing - see Diagram C
2.
  Slip flat metal washer onto anchor bolts. 
3.  Slip pole base over anchor bolts and check for plum.  If pole is not plum adjustments can be made to 
hex nuts under base to correct any leaning.
4.  When pole is plum finish installation by threading on the and tightening the cap nuts provided.

FOOTING DETAIL VIEW

  

Diagram C

 

FLAT WASHER

     

revised 12-01-10