WARNING

     SECTION 1: GENERAL INFORMATION

Do not take a sauna if using 

alcohol, drugs or 

medications.

Pregnant women or persons 

with poor health should 

consult their physician before 

using any sauna.

Caution re hazard: Do not 

use the sauna room for 

drying clothes, bathing suits, 

etc. Do not hang towels 

above heater or place any 

object other than the rocks 

supplied on the heater.  If any 

darkening of the wall around 

the heater is noticed 

discontinue sauna use 

immediately.

Inspect sauna regularly for 

required maintenance to 

heater, control and benches. 

Replace wood surfaces 

which show any signs of 

deterioration.

The heater gets extremely hot 

during operation and should 

not be touched or burns may 

result.

Minors should be adequately 

supervised whenever near a 

hot or warming sauna.

Himalaya “Premium" Series Sauna Heaters 

Models 7.0, 9.0 

(Type #'s 1118-702-1707, 1118-902-1707)

 

w

ith

 Premium Control 

(Type # 

1601-33 and 1601-33-1)

 And/Or 

Trend Control 

(Type # 1601-31 and 1601-31-1)

.

Read all instructions carefully before installation. Please leave all 
instructions and warranty with the owner. 

WARNING
Prolonged  exposure  to  elevated  temperatures  is  capable  of  inducing 
hyperthermia.  Hyperthermia  occurs  when  the  internal  temperature  of  the 
body  reaches  several  degrees  above  the  normal  body  temperature  of 
98.6°F. The symptoms of hyperthermia include an increase in the normal 
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The 
effects  of  the  hyperthermia  include  failure  to  perceive  heat,  failure  to 
recognize  the  need  to  exit  the  room,  unawareness  of  impending  hazard, 
fetal  damage  in  pregnant  women,  physical  inability  to  exit  the  room  and 
unconsciousness.

WARNING
The use of alcohol, drugs, or medication is capable of greatly increasing 
the risk of fatal hyperthermia.

These heaters are ETL approved by Intertek for permanent installations and 
electrical connections.  Built with splash proof construction, the conducting 
parts are protected against water.  All wiring must be performed in 
accordance with national and local codes.  See Diagram 2 for wire and 
room size requirements. These heaters are oor mounted.

Premium 

Control

1601-33 or 

1601-33-1

Trend 

Control

1601-31 or 

1601-31-1

Summary of Contents for Premium 7.0

Page 1: ...1 and 1601 31 1 Read all instructions carefully before installation Please leave all instructions and warranty with the owner WARNING Prolonged exposure to elevated temperatures is capable of inducing...

Page 2: ...wer Supply to Heater 1 208 32 7 2 8AWG N GR 1 240 28 3 2 8AWG N GR 3 208 18 9 3 10AWG N GR 3 240 16 4 3 10AWG N GR 1 208 43 3 2 6AWG N GR 1 240 37 5 2 6AWG N GR 3 208 25 0 3 8AWG N GR 3 240 21 7 3 10A...

Page 3: ...stems used inside any sauna room should be properly rated for sauna room temperatures Do not place hands and or arms over the BWT when hot Steam from BWT may cause severe burns Do not pour chlorinated...

Page 4: ...crewdriver tip here to unsnap sensor cover from sensor Note vertical orientation of cover before removing Bracket ts in any hexagon opening and then screws to the wall or bench Sensor protective cover...

Page 5: ...7 A1 2 4 6 8 A2 X1 X2 X3 X5 X7 X4 X6 X8 X13 X14 N N H 2 3 Trans former 120 Volt Light Output 2 0 Amp Max Contactor High Limit Switch 1601 33 or 1 2 3 4 5 6 GND 1601 33 1 Breaker 2 Amp 4 Control Ports...

Page 6: ...2 X3 X5 X7 X4 X6 X8 N N H Trans former 120 Volt Light Output 2 0 Amp Max Contactor High Limit Switch 1 2 3 4 5 6 GND Breaker 2 Amp L1 L2 L3 1 2 3 4 5 6 Three Phase Connections Three Phase Connections...

Page 7: ...or outside the sauna room If the control is installed inside a sauna room the top of the unit cannot be higher than 48 inches above oor Maximum control cable length is 50 feet String the provided low...

Page 8: ...s button touch this to display the Settings screen Here you can adjust the temperature and duration for the current bath You can also manually turn on the installed options when the bath is on and tur...

Page 9: ...e Stop After button Change to desired length normal setting is 1 hour Press the to accept the change Creating Favorites Ensure temperature and sauna length are correct Press Save as Favorite Type in N...

Page 10: ...nt Select the sauna duration and temperatures Press the to accept information Calendar Showing Event Scheduled The indicated a program is scheduled on the date Select the button at the top of screen t...

Page 11: ...Select the WiFi option from Setting Screen Select Network Option Select Name Select Name and name the Control Enter Name and select to accept Choose WiFi Network Select Scan to see all Wi Networks Se...

Page 12: ...plication Home Screen Select the Settings icon Network Select network Choose Sauna Control Phone must be connected to the same network as Sauna Control Press Find System Choose Control Connect to Cont...

Page 13: ...the heater C On Off Sauna Switch and fault alarms D Sets the desired value E Functions Temperature Delay Timer Sauna Length and Humidity n a F Function Select Buttons CONTROL OPERATION TURN ON LIGHT P...

Page 14: ...ult After 10 minutes or when perspiration begins leave sauna and relax in dressing area follow with a cool shower Cooling time should equal time spent in sauna Enter sauna room again and stay 5 or 10...

Page 15: ...NTILATION DIAGRAM 9 DIAGRAM 10 1 Put smaller rocks in rst around the outer perimeter of the heating elements in layers 2 Fill the middle sections with larger rocks 3 Ensure the elements are vertical w...

Page 16: ...ds No shower may be installed in a sauna room No electrical receptacle shall be installed inside the sauna room The enclosed WARNING Reduce the risk of overheating warning plate must be mounted on or...

Page 17: ...inse before putting BWT back into the heater SECTION 12 VENTILATION VENTILATION In a sauna the air should be changed about 6 times an hour This can be achieved by making a vent opening fresh air inlet...

Page 18: ...auna heater and should not exceed 194 F 90 C Air temperature will be 15 F to 25 F lower on the opposite side of the room from the heater close to the ceiling The temperatures in the elevated view are...

Page 19: ...NT HTR 3000W 240V SEPC 238 1 HIMALAYA 3 7 8250 086 BRKT HTR HIMALAYA 70 90 MOUNTING 1 8 8201 115 BRKT HOLDER HIGH LIMIT HIMALAYA HTR 1 9 8012 527 SHROUD HTR HIMALAYA BLK OUTER 1 10 3119 510 SWITCH HIG...

Page 20: ...error code will be displayed with a constant LED light or a ashing LED light under numbers 1 10 See the list below for fault codes Constant LED Fault Code ones marked with n a are not in use 1 Tempera...

Page 21: ...INSTALLATION AND OPERATING INSTRUCTIONS 72 0112 03 06 18 7013500 314 SKLT 69 A Page 21 SECTION 16 INSTALLATION PREMIUM CONTROL 1601 33 or 1601 33 1 OPERATION Page Intentially Left Blank...

Page 22: ...e mounting screws to pull the tab tight against the inside of the wall Ensure the box is level and the correct end is UP there is an arrow on the wall side of the box pointing up PLATED COVER RING Con...

Reviews: