I n
K 1
N O
*
P l a y
#
R e c
I n
K 1
S I
*
P l a y
#
R e c
I n
K 2
N O
*
P l a y
#
R e c
I n
K 2
S I
*
P l a y
#
R e c
I N T 1
N O
*
P l a y
#
R e c
I N T 1
S I
*
P l a y
#
R e c
I N T 2
N O
*
P l a y
#
R e c
I N T 2
S I
*
P l a y
#
R e c
O u t
1
N O
*
P l a y
#
R e c
O u t
1
S I
*
P l a y
#
R e
O u t
2
N O
*
P l a y
#
R e c
O u t
2
S I
*
P l a y
#
R e c
Not active description for channel 1 input
Not presence voltage description for +12V on INT1
Not presence voltage descript12V su INT2
Not active description for out 1 output
3.4
Text
messages
Using this menu, it is possible to insert or modify all the descriptions which appear
on the display of the combiner to indicate the status of the inputs and outputs.
These descriptions will then be displayed when the interrogation commands or
input and output commands are keyed on the keypad (see para 4.2.3).
!
Key in the code:
(Default MASTER code)
!
Press the button:
(Programming)
!
Press the button:
(
Text Message
)
!
This will be displayed:
!
Press the button:
or
!
This will be displayed
!
Key the description to be stored
For exmaple:
!
Press the button:
Once the description to be stored has been keyed in, use the
or
keys and
then press the
or
key store the others.
A table of the status of the inputs and outputs which can be described is then
I n
K 1
N O
I n
K 1
N O
_
I n
K 1
N O
I n
K 1
>
_
I n
K 1
N O
I r r i g a t i o n
>
_ _
12
TD96 / TM96P - User manual
Active description for channel 1 input
Not active description for channel 2 input
Active description for channel 2 input
Presence voltage description for +12V on INT1
Presence voltage description for +12V on INT2
Active description for out 1 output
Not active description for out 2 output
Active description for out 2 output
13
3.5
Channels
With this menu, it is possible to establish how the two channels of the combiner
must be activated.
!
Key in the code:
(Default MASTER code)
!
Press the button:
(Programming)
!
Press the button:
(
Channels
)
!
This will be displayed
!
Press the button:
or
!
This will be displayed
!
Press the button:
or
!
This will be displayed
Choose between the displays depicted in the table under which condition the
channel is alarmed, using the
or
keys. Then press the
or
.
C H A N N E L
S E L E C T
C h a n n e l
1
_
C h a n n e l
1
A c t i v a t i o n
A c t i v a t i o n
N O
I m p u l s e
_
The channel is activated from the presence of a
positive 12Vcc to the input of the channel; the cycle
of calls comes started and carried out until the term,
if not interrupted through commandos..
The channel is activated from the absence of a
positive 12Vcc on the input of the channel; the cycle
of calls comes started and carried out until the term,
if not interrupted through commandos
The channel is active to the presence of apositive
one 12Vcc on the input of the channel; the cycle
of calls comes activated and carried out until the term,
if not interrupted through commandos
or the absence of the positive one 12Vcc on the input.
0
12V
Impulse NO
0
12V
Impulse NC
0
12V
Level NO
Level NC
0
12V
The channel is active to lacking the positive one 12Vcc
on the income of thechannel; the cycle of calls comes
activated and carriedout until the term, if not interrupted
through commandos or the restoration of the positive
one 12Vcc on the income
A c t i v a t i o n
N O
L e v e l
_
A c t i v a t i o n
N O
L e v e l
_
A c t i v a t i o n
N C
I m p u l s e
_
A c t i v a t i o n
N O
I m p u l s e
_
A c t i v a t i o n
N o t
A c t i v e
_
The active channel in no condition and on the first
one display of the combinatore is not come visualized:
R e a d y
. . . . . . . . . .
C H 1
D i s a b l e d
_
Programmation
security
security