ing area.
Untidiness at the workplace can lead to
accidents.
c)
If the work involves breaking right through, take
the appropriate safety measures at the opposite
side
. Parts breaking away could fall out and / or fall
down and injure other persons.
d)
Approval must be obtained from the site engineer
or architect prior to beginning the work. Work
on buildings and other structures may influence
the statics of the structure, especially when steel
reinforcing bars or load-bearing components are
cut through.
3 Description
3.1 Use of the product as directed
The power tool is an electrically-powered breaker with
electropneumatic hammering mechanism designed for
heavy chiseling work.
The power tool is designed for breaking / removing and
demolishing concrete, masonry, stone or asphalt.
Observe the national health and safety requirements.
The power tool is designed for professional use and may
be operated, serviced and maintained only by trained,
authorized personnel. This personnel must be informed of
any special hazards that may be encountered. The power
tool and its ancillary equipment may present hazards
when used incorrectly by untrained personnel or when
used not as directed.
The power tool may be operated only when connected
to a power supply providing a voltage and frequency
in compliance with the information given on its type
identification plate.
To avoid the risk of injury, use only genuine Hilti acces-
sories and insert tools.
3.2 Active Vibration Reduction (TE 800‑AVR)
The power tool is equipped with an AVR active vibration
reduction system which reduces vibration significantly
compared to power tools without active vibration reduc-
tion.
3.3 Protective features
Vibration reduction and high-temperature protection pro-
vided by isolation of the grips and plastic casing from
internal parts of the power tool.
Electronic restart interlock to prevent the power tool
starting unintentionally after an interruption in the electric
supply (see section “Troubleshooting”).
3.4 LED indicators
Service indicator LED (see section “Care and mainte-
nance / service indicator”)
Power level indicator (see section “Operation / setting
chiseling power”)
3.5 Standard equipment includes:
1 Power tool
1 Side handle
1 Operating instructions
NOTE
Accessories can be found at your Hilti Center or online at
www.hilti.com
.
4 Technical data
Right of technical changes reserved.
NOTE
When powered by a generator or transformer, the generator or transformer’s power output must be at least twice the
rated input power shown on the rating plate of the power tool. The operating voltage of the transformer or generator
must always be 5% and -15% of the rated voltage of the power tool.
Power tool
TE 800‑AVR
TE 800
Rated voltage
120 V
120 V
Rated current input
15 A
15 A
Mains frequency
60 Hz
60 Hz
Weight
10.6 kg (23.37 lb)
10.5 kg (23.15 lb)
Single impact energy
21 J
21 J
Hammering frequency under load
31.5 Hz
31.5 Hz
Chuck
TE‑S
TE‑S
en
4
Printed: 14.10.2015 | Doc-Nr: PUB / 5210095 / 000 / 01