18
English
2130485
*2130485*
Storage temperature
−20 ℃ … 40 ℃
Battery charging starting temperature
−10 ℃ … 45 ℃
4.3
Noise information and vibration values determined in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance with
a standardized test and may be used to compare one electric tool with another. They may be used for a
preliminary assessment of exposure.
The data given represents the main applications of the electric tool. However, if the electric tool is used for
different applications, with different accessory tools, or is poorly maintained, the data may vary. This may
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period.
Prescribe additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
SF 10W-A22
Emission sound pressure level (L
pA
)
75 dB(A)
Uncertainty for the sound pressure level (K
pA
)
3 dB(A)
Sound (power) level (L
WA
)
86 dB(A)
Uncertainty for the sound power level (K
WA
)
3 dB(A)
Total vibration
SF 10W-A22
Vibration emission value for screwdriving (a
h
)
< 2.5 m/s²
Uncertainty for screwdriving (K)
1.5 m/s²
Drilling in metal (a
h,D
)
< 2.5 m/s²
Uncertainty for drilling in metal (K)
1.5 m/s²
5
Preparations at the workplace
CAUTION
Risk of injury by inadvertent starting!
▶
Before inserting the battery, make sure that the product is switched off.
▶
Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Inserting the battery
CAUTION
Risk of injury by short circuit or falling battery!
▶
Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶
Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the battery holder until it engages with an audible click.
3. Check that the battery is seated securely.
5.2
Removing the battery
1. Press the battery release buttons.
2. Remove the battery from the tool.