background image

5.3.2 Power tool use and care

a)

Secure the workpiece. Use clamps or a vice
to secure the workpiece.

The workpiece is thus

held more securely than by hand and both hands
remain free to operate the power tool.

b)

Check that the insert tools used are compatible
with the chuck system and that they are secured
in the chuck correctly.

c)

Take care to ensure that metal cuttings do not
find their way into the tool or battery.

d)

Empty the chip collector and clean the power
tool before putting it away in the toolbox or other
container for storage or transport.

Metal chips

may otherwise fall out of the collector and find
their way into the power tool, battery or charger,
presenting a risk of damage or malfunction.

5.3.3 Electrical safety

Before beginning work, check the working area
(e.g. using a metal detector) to ensure that no
concealed electric cables or gas and water pipes
are present.

External metal parts of the power tool

may become live, for example, when an electric cable
is damaged accidentally. This presents a serious risk
of electric shock.

5.3.4 Battery use and care

a)

Observe the special instructions applicable to
the transport, storage and use of Li-ion batter-
ies.

b)

Do not expose batteries to high temperatures or
fire.

This presents a risk of explosion.

c)

Do not disassemble, squash or incinerate bat-
teries and do not subject them to temperatures
over 80°C (176°F).

A risk of fire, explosion or

injury through contact with caustic substances
may otherwise result.

d)

Do not use batteries other than those approved
for use with the applicable power tool or appli-
ance.

Use of other batteries or use of the battery

for purposes for which it is not intended presents
a risk of fire and explosion.

e)

Do not charge or continue to use damaged bat-
teries (e.g. batteries with cracks, broken parts,
bent or pushed-in and/or pulled-out contacts).

f) If the battery gets too hot to touch, this may indi-

cate that it is faulty.

Place the tool at a location

where there is no risk of causing a fire (at least 3
meters away from flammable materials), where
it can be kept under observation and allowed to
cool. Contact Hilti Service after the battery has
been allowed to cool.

5.3.5 Work area

a)

Ensure that the workplace is well lit.

b)

Ensure that the workplace is well ventilated.

Exposure to dust at a poorly ventilated workplace
may result in damage to the health.

5.3.6 Personal protective equipment

The user and any other persons in the vicinity must
wear ANSI Z87.1-approved eye protection, a hard
hat, ear protection, protective gloves and breathing
protection while the machine is in use.

5.3.7 Safety precautions

Do not switch the power tool on if the saw blade,
the blade guard or the pivoting guard are not fitted
correctly.

en

9

Summary of Contents for SCM 18-A

Page 1: ...2019523 2019523 SCM 18 A Operating instructions en Mode d emploi fr Manual de instrucciones es Manual de instru es pt...

Page 2: ...1 This Product is Certified Ce produit est homologu Producto homologado por Este produto est registrado C US...

Page 3: ...4 6 2 3 5...

Page 4: ...ar saw Operating controls and indicators 1 Battery Release buttons with additional function charge status display activation Charge status and fault display lithium ion battery On off switch Switch on...

Page 5: ...tions before use Return waste material for recycling Volts Direct current Rated speed under no load Revolutions per minute Revolutions per minute Diameter Saw blade Location of identification data on...

Page 6: ...sum board gypsum fiberboard and composite materials Do not use the battery as a power source for other unspecified appliances To avoid the risk of injury use only genuine Hilti accessories and insert...

Page 7: ...NOTE Depending on the version these items may be supplied with the power tool 3 Insert tools accessories Accessories for the SCM 18 A Designation Short designation Charger for Li ion batteries C 4 36...

Page 8: ...efers to your mains operated corded power tool or battery operated cordless power tool 5 1 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not oper...

Page 9: ...itch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source and or the battery pack from the...

Page 10: ...ly by the kerf closing down the blade stalls and the motor reaction drives the unit rapidly back toward the operator if the blade becomes twisted or misaligned in the cut the teeth at the back edge of...

Page 11: ...the power tool h Always guide the power tool away from your body when working with it i Do not work with the power tool overhead j Do not attempt to brake the speed of the saw blade by pressing it to...

Page 12: ...osion c Do not disassemble squash or incinerate bat teries and do not subject them to temperatures over 80 C 176 F A risk of fire explosion or injury through contact with caustic substances may otherw...

Page 13: ...uctions for the charger for further information about the charging procedure Lithium ionbattery packs are ready to use at any time even when only partially charged Charging progress is indicated by th...

Page 14: ...rationgeneratenoise Exposureto noisecancause loss of hearing CAUTION Secure the workpiece Use clamps or a vice to secure the workpiece This will help to prevent vi bration CAUTION Do not saw off very...

Page 15: ...te on the workpiece but do not bring the blade into contact with the workpiece 6 If the switch on interlock has been pressed switch the power tool on by pressing the on off button 7 Guide the saw alon...

Page 16: ...s a significant drop in performance is noticed NOTE If use of the power tool continues further battery discharge will be stopped automatically before the battery cells suffer damage Charge the battery...

Page 17: ...art the saw The power tool doesn t work and all 4 LEDs blink The power tool has been over loaded Release the control switch and press it again The overheating prevention cut out has been activated All...

Page 18: ...ranty tools Hilti warrants that the tool supplied is free of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced prope...

Page 19: ...ration LI 9494 Schaan Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 4082 0312 00 Pos 3 1 Printed in China 2012 Right of technical and programme change...

Reviews: