![Hilti HIT-ICE Manual Download Page 14](http://html1.mh-extra.com/html/hilti/hit-ice/hit-ice_manual_2134860014.webp)
Adhesive Anchoring Systems
HIT-ICE Adhesive Anchoring System 3.2.5
3.2.5
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 213
Table 23 - Open gel time
1,2
Base material temperature
HIT-ICE
°F
°C
–10
–23
1.5 h
0
–18
1.5 h
23
–5
40 min
32
0
26 min
41
5
11 min
68
20
4 min
86
30
1.5 min
Table 24 - Full cure time
1,2
Base material temperature
HIT-ICE
°F
°C
–10
–23
36 h
0
–18
24 h
23
–5
6 h
32
0
4 h
41
5
2 h
68
20
1 h
86
30
30 min
1 Product temperatures must be maintained above
0°F (–18°C) prior to installation.
2 Gel times and full cure times are approximate.
Base material temperature °F
Allowable bond strength
% of load at 70°F
Figure 5 - Influence of temperature on bond strength
1,2
1 Test procedure involves the concrete being held at the elevated
temperature for 24 hours them removing it from the controlled
environment and testing to failure.
2 Long term creep test in accordance with ICC-ES Acceptance
Criteria AC58.
3.2.5.4 Installation instructions
Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online
at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU
are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti
Technical Services for applications and conditions not addressed in the IFU.
HIT-ICE Volume
Table 25 - Threaded rod installation
Nominal
anchor
diameter
in.
Drill bit
diameter
in.
Adhesive volume
required
per Inch of
embedment in
3
1
/
4
5
/
16
0.055
3
/
8
7
/
16
0.095
1
/
2
9
/
16
0.133
5
/
8
11
/
16
0.184
3
/
4
13
/
16
0.232
7
/
8
24mm
0.272
1
1-1
/
16
0.366
1-1
/
4
1-1
/
2
0.918
Example:
A HIT-ICE cartridge contains a useable
volume of 18 in
3
. So, for a 5/8-in. diameter
rod with an embedment of 10 inches:
10 in. x 0.184 in
3
/in. =1.84 in
3
/fastening
18 in
3
/cartridge ÷ 1.84 in
3
/fastening = 10
fastenings/cartridge
Table 26 - Rebar installation
1
Rebar
size
Nominal bit
1
diameter
in.
Adhesive
volume
required
per Inch of
embedment
in
3
#3
1
/
2
0.110
#4
5
/
8
0.146
#5
3
/
4
0.176
#6
7
/
8
0.218
#7
1
0.252
#8
1-1
/
8
0.299
#9
1-3
/
8
0.601
#10
1-1
/
2
0.659
#11
1-3
/
4
1.037
1 Rebar diameter may vary. Use smallest drill bit
which will accommodate rebar.
Table 27 - CA rebar installation
c
Bar
Diameter
Drill Bit
1
Diameter
Adhesive volume
required
per Inch of
embedment (in.
3
)
10M
14 mm
0.101
15M
3
/
4”
0.176
20M
24 mm
0.268
25M
1-1
/
8”
0.309
30M
37 mm
0.644
35M
1-9
/
16”
0.480