background image

page 2 

February 2014

Product Data Sheet

HIT-HY 200 
with HIT-Z

Approvals / certificates

Description

Authority / Laboratory

No. / date of issue

European technical approval 

a)

DIBt, Berlin

ETA-12/0028 / 2013-03-15
(HIT-HY 200-R)

Fire test report 

IBMB, Brunswick 

3501/676/13 / 2012-08-03

a)  All data given in this section according ETA-12/0028, issue 2013-03-15.

Working time, curing time

Temperature of the base material

HIT-HY 200-R

Working time in which anchor  

can be inserted and adjusted t

work

Curing time before anchor  

can be loaded t

cure

5 °C

1 hour

3 hour

6 °C to 10 °C

40 min

2 hour

11 °C to 20 °C

15 min

1 hour

21 °C to 30 °C

9 min

1 hour

31 °C to 40 °C

6 min

1 hour

Anchor size

M8

M10

M12

M16

M20

Nominal diameter of drill bit 

d

0

[mm]

10

12

14

18

22

Effective embedment and drill hole depth 

range a) for HIT-V

 

h

nom,min

[mm]

60

60

60

96

100

h

nom,max

[mm]

100

120

150

200

220

Minimum base material thickness 

h

min

[mm]

h

nom

 + 60

h

nom

 + 100

Pre-setting: 

Diameter of clearancehole in the fixture

d

[mm]

9

12

14

18

22

Through-setting: 

Diameter of clearance hole in the fixture

d

[mm]

11

14

16

20

24

Torque moment

T

max 

[Nm]

10

25

40

80

150

Setting details