Basic loading data (for a single anchor)

All data in this section applies to

  

Correct setting (See setting instruction)

  

No edge distance and spacing influence

  

Steel failure

  

Base material thickness, as specified in the table

  

Embedment depth, as specified in the table

  

One anchor material, as specified in the tables

  

Non cracked concrete f

c,cyl

 = 32 MPa

    

Temperate range I (min. base material temperature -40°C, max. 

long term/short term base material temperature: +24°C/40°C)

  

Installation temperature range -10°C to +40°C

Embedment depth and base material thickness for the basic loading data

Recommended loads

Anchor size

M8

M10

M12

M16

M20

Typical embedment depth h

ef 

[mm]

80

90

110

145

180

Base material thickness h [mm]

140

150

170

245

280

Recommended loads 

Anchor HIT-Z

Anchor size

M8

M10

M12

M16

M20

Tensile N

rec

  

 [kN]

11.4

18.1

25.9

45.7

69.5

Shear V

rec

  

 [kN]

6.9

10.9

15.4

27.4

41.7

Note: For varied embedment depths please contact your local Hilti engineer for further details.

Hilti HIT-HY 200 with HIT-Z

Injection Mortar System

Benefits

  no cleaning required: zero 

succeptability to borehole cleaning 

conditions with dry and water 

saturated concrete base material

  maximum load performance in 

cracked concrete and uncracked 

concrete

  suitable for cracked and non-cracked 

concrete C 20/25 to C 50/60

  suitable for use with diamond cored 

holes in non-cracked or cracked 

concrete with no load reductions

Hilti HIT-HY 200-R

500 ml foil pack

(also available as 330 ml 

foil pack)

Static mixer

HIT-Z

HIT-Z-R rod

CE 

conformity

European 

Technical 

Approval

Concrete

A4 

316

Corrosion 

resistance

Tensile 

zone

PROFIS 

anchor design

software

No cleaning

required for

approved

loads

Seismic

Diamond 

drilled 

holes

Reviews: