Hilti DX 860-ENP Operating Instructions Manual Download Page 15

10

en

If these measures fail to remedy the problem, please contact Hilti.

Fastener stand-off varies
considerably. 

F

Shear breakage. 

C

The tool remains
 compressed (does not
extend when pressure
is released).

The tool cannot be fired.

No fastener is driven.

The base plate cannot be
screwed on to the tool
fully.

The piston cannot be
 fitted.
The piston guide cannot
be fitted.

Stiff cycling action (high
force required to press
the tool down).

Irregular driving power.

Fastener driven into the rib of the
beam.
The supporting material is thicker
and/or of higher strength.

The piston is jammed against the
 piston  stopper.
The tool needs to be cleaned.
The cartridge strip has jammed, the
tool has overheated.

Trigger pulled before the tool is fully
pressed down.
Fastener transport malfunction.

The tool needs to be cleaned.
The base plate and fastener transport
system are not screwed on fully.
The tool is damaged.
Fastener strip transport mechanism is
defective.
No piston in the tool.
The piston is broken.
The base plate needs to be cleaned.

Fasteners are jammed in the base
plate.

The piston stopper has been inserted
the wrong way round.

The piston guide needs to be cleaned
at the end of the threaded section.
The tool, the piston guide in particular,
needs to be cleaned.
The catch remains in the closed  position.
The piston guide is incorrectly
 positioned.
The tool needs to be cleaned.

Clean the tool. Replace the wearing
parts. Contact Hilti if irregular driving
power is still experienced.
Reposition the tool and drive another
fastener.
Check that the recommended type of
 fastener is being used and then increase
driving power in accordance with
 recommendations for the cartridge or,
respectively, use a more powerful
 cartridge.
Replace the piston and piston stopper.

(7.4.2)

Clean the tool. 

(8.2.2)

Please refer to “Cartridge strip cannot
be removed.”
Do not exceed the maximum
 recommended fastener driving rate.
Press the tool down fully and then pull
the trigger.
Load fastener strip 

(7.2.1)

; check that

strip is free to move; remove any dam-
aged or distorted fasteners 

(7.3.2)

.

Clean the tool.

(8.2.2)

Screw the base plate and fastener
 transport system on fully.
Contact Hilti.
Contact Hilti.

Fit the piston.
Replace the piston and piston stopper.
Use the brushes provided to clean the
base plate and associated parts.
 Lubricate with Hilti spray.
Remove the jammed fasteners. 
Avoid shear breakage (see above).
Avoid missing the beam (driving the
 fastener into unsupported sheet metal);
mark the position of the beams
 accurately if necessary.
Unscrew and remove the base plate. Fit
the piston stopper the right way round
and screw on the base plate.
Clean and lubricate the thread.

Clean the piston guide and refit the
 piston.
Open the catch. 

(8.2.2)

Position the piston guide correctly when
inserting it. 

(8.2.2)

Clean the piston guide. Check the piston
for straightness.
Clean the tool.

(8.2.1 and 8.2.2)

Printed: 10.04.2017 | Doc-Nr: PUB / 5126862 / 000 / 00

Printed: 10.04.2017 | Doc-Nr: PUB / 5126862 / 000 / 01

Summary of Contents for DX 860-ENP

Page 1: ...202946 Operating instructions en Mode d emploi fr Manual de instrucciones es DX 860 ENP Printed 10 04 2017 Doc Nr PUB 5126862 000 00 Printed 10 04 2017 Doc Nr PUB 5126862 000 01...

Page 2: ...1 Printed 10 04 2017 Doc Nr PUB 5126862 000 00 Printed 10 04 2017 Doc Nr PUB 5126862 000 01...

Page 3: ...h h h h h max min max min 2 3 4 5 6 7 8 9 1 2 4x 1 2 2 1 A B C D E F 2 1 2 1 3 4 3 2 2 4 1 Printed 10 04 2017 Doc Nr PUB 5126862 000 00 Printed 10 04 2017 Doc Nr PUB 5126862 000 01...

Page 4: ...3 4 3 High strength steel S 355 S275 E 42 ST 52 490 630 N mm2 Base material thickness mm 4 3 4 3 20 15 10 8 6 X ENP red black blue red 10 11 2 1 3 7 4 5 11 10 9 8 Printed 10 04 2017 Doc Nr PUB 5126862...

Page 5: ...12 13 14 3 2 1 4 5 6 7 8 9 10 11 11 12 13 14 15 16 17 Printed 10 04 2017 Doc Nr PUB 5126862 000 00 Printed 10 04 2017 Doc Nr PUB 5126862 000 01...

Page 6: ...11 12 Health and safety of the operator 27 Parts of the tool DX 860 ENP powder actuated fastening tool Cartridge loading channel Catch Base plate Grip and trigger mechanism Cartridge strip exit point...

Page 7: ...ple Extra heavy 27 CAL long red Heavy 27 CAL long blue 3 3 Wearing parts Ordering designation Comments X 76 PS X 76 P ENP Piston stopper Piston 3 4 Accessories Ordering designation Comments Cleaning s...

Page 8: ...lace Ensure that the working area is well lit Operate the tool only in well ventilated working areas The tool is for hand held use only Keep other persons away from the working area espe cially childr...

Page 9: ...cartridge on the strip by cycling the tool Use up the remaining cartridges on the strip and remove the used cartridge strip from the tool The partly used cartridge strip must then be disposed of suita...

Page 10: ...driven deeply enough driving power must be increased Adjust the power regulation wheel to the next higher setting 5D If a fastener is driven too deeply driving power must be decreased 5E Adjust the p...

Page 11: ...ss the tool fully against the work surface and pull the trigger 2 If the cartridge still fails to fire lift the tool away from the work surface Do not point the tool toward your self or other persons...

Page 12: ...ainst the piston stopper the piston and piston stopper must be replaced NOTE Check the piston for straightness by rolling it on a smooth surface Never use a worn or damaged piston and do not tam per w...

Page 13: ...ti spray NOTE Use of lubricants other than Hilti lubricant spray may cause damage to rubber parts of the tool especially the piston stopper 10 Lubricate the moving part of the fastener transport syste...

Page 14: ...l to cool down and then try again to carefully remove the cartridge strip If still not possible contact Hilti NOTE Do not attempt to forcibly remove cartridges from the strip or from the tool See Reme...

Page 15: ...ean the tool Replace the wearing parts Contact Hilti if irregular driving power is still experienced Reposition the tool and drive another fastener Check that the recommended type of fastener is being...

Page 16: ...ponents and spare parts or other products of equivalent quality may be used in the tool This warranty provides the free of charge repair or replacement of defective parts only over the entire lifes pa...

Page 17: ...15895 1 in the semi anechoic test room of Mu ller BBM GmbH The ambient conditions in the test room conform to DIN EN ISO 3745 Testing procedure Enveloping surface method in anechoic room on reflective...

Page 18: ...2965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2973 1112 00 Pos 2 1 Printed in Liechtenstein 2012 Right of technical and programme changes reserved S E O 202946 A2 Printed 10 04...