background image

English

7

=

On/off switch

%

Dust extr. hood

&

Adjusting lever for segment opening

(

Height adjustment of the dust extr. hood

)

Pin wrench

+

Clamping nut

§

Diamond cup wheel

/

Mounting flange

:

Arbor

Grinding pad for precision grinding

$

Mounting flange for grinding pad

£

Adjusting knob for speed

3.3

Items supplied

Diamond grinder, operating instructions, clamping nut and flange.

To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare

parts, consumables and accessories approved by Hilti for use with the product can be found at your local

Hilti Store

or online at:

www.hilti.group

| USA:

www.hilti.com

3.4

Starting current limitation

The electronic starting current limiter reduces the starting current drawn by the power tool and thus prevents

the mains fuse blowing. It also allows the power tool to start smoothly, without a jolt.

3.5

Constant-speed electronics

Electronic speed control keeps running speed almost constant irrespective of whether the power tool is

idling or running under load. Constant running speed helps ensure maximum efficiency.

3.6

Active Torque Control (ATC)

The electronics detect potential stalling of the disc and prevent further rotation of the arbor by switching off

the tool.

If the ATC system has been triggered, restart the tool. Do this by releasing the on/off switch and then

pressing it again.

If the ATC system malfunctions, the power tool will run only at greatly reduced speed and with greatly

reduced torque. Have the tool checked by

Hilti

Service.

3.7

Restart interlock

The power tool does not restart by itself when the on/off switch is locked in the on-position and the power

returns after an interruption in the electric supply. The on/off switch must first be released and then pressed

again to restart.

3.8

Temperature-dependent motor protection

The temperature-dependent motor protection system monitors current input and motor temperature and

thus prevents the power tool overheating.

If the motor is overloaded through application of excessive working pressure, the power tool’s performance

drops noticeably or it may stop completely. A standstill should be avoided. No specific value can be given

for the permissible overloading limit for the power tool as it depends on motor temperature.

4

Technical data

For rated voltage, rated current, frequency and/or input power, refer to the country-specific type

identification plate.

If the device is powered by a generator or transformer, the generator or transformer’s power output must be

at least twice the rated input power shown on the rating plate of the device. The operating voltage of the

transformer or generator must always be 5 % and -15 % of the rated voltage of the device.

DGH 130

Weight

2.54 kg

Rated speed

12,000 /min

Printed: 05.09.2018 | Doc-Nr: PUB / 5450687 / 000 / 00

Summary of Contents for DGH 130

Page 1: ...DGH 130 English Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 2: ...Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 3: ...DGH 130 English Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 4: ...Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 5: ...CAUTION Draws attention to a potentially dangerous situation that could lead to slight personal injury or damage to the equipment or other property 1 2 2 Symbols in the documentation The following symbols are used in this document Read the operating instructions before use Instructions for use and other useful information Dealing with recyclable materials Do not dispose of electric equipment and b...

Page 6: ...rectives and standards A copy of the declaration of conformity can be found at the end of this documentation The technical documentation is filed here Hilti Entwicklungsgesellschaft mbH Tool Certification Hiltistrasse 6 86916 Kaufering Germany 2 Safety 2 1 General power tool safety warnings WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may re...

Page 7: ...ght in moving parts If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards Power tool use and care Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designe...

Page 8: ...ate area of operation Hold the power tool by insulated gripping surfaces only when performing an operation where the cutting accessory may contact hidden wiring or its own cord Cutting accessory contacting a live wire may make exposed metal parts of the power tool live and could give the operator an electric shock Position the cord clear of the spinning accessory If you lose control the cord may b...

Page 9: ...ns Personal safety Always hold the machine securely with both hands on the grips provided Do not touch electrically grounded parts Do not use the device in extremely dusty conditions There is a risk of burning or cutting injuries Wear protective gloves when handling the power tool or changing the accessory tool Wear ear protectors Exposure to noise can cause hearing loss Make sure that the workpla...

Page 10: ...6 English 3 2 Overview Connector for dust extraction Arbor lockbutton Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 11: ...releasing the on off switch and then pressing it again If the ATC system malfunctions the power tool will run only at greatly reduced speed and with greatly reduced torque Have the tool checked by Hilti Service 3 7 Restart interlock The power tool does not restart by itself when the on off switch is locked in the on position and the power returns after an interruption in the electric supply The on...

Page 12: ...anization of work patterns Noise information Sound power level LWA 96 3 dB A Uncertainty for the sound power level KWA 3 dB A Emission sound pressure level LpA 85 3 dB A Uncertainty for the sound pressure level KpA 3 dB A Vibration information Vibration emission value diamond cup wheel ah 3 6 m s Vibration emission value fine grinding ah 3 1 m s Uncertainty K 1 5 m s 5 Preparations at the workplac...

Page 13: ...ion of the on off switch The on off switch jumps into the off position and the motor stops 6 2 Trying out after fitting a new diamond cup wheel CAUTION Risk of injury Damaged diamond cup wheels can come loose Do not use a diamond cup wheel if it vibrates protect the cup wheel against impact shock loading and grease Allow the power tool to run for at least 1 minute without load 6 3 Grinding 1 Conne...

Page 14: ...sure safe and reliable operation use only genuine Hilti spare parts and consumables Spare parts consumables and accessories approved by Hilti for use with the product can be found at your local Hilti Store or online at www hilti group USA www hilti com 7 1 Changing the grinding slats Change the grinding slats when they are worn 1 Remove the accessory tool page 8 2 Pull the dust lips out of the gua...

Page 15: ...nder no load until it has cooled down 10 Disposal Most of the materials from which Hilti tools and appliances are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries your old tools machines or appliances can be returned to Hilti for recycling Ask Hilti Service or your Hilti representative for further information Do not dispose of pow...

Page 16: ...12 English Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 17: ...Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Page 18: ...Hilti registered trademark of Hilti Corp Schaan 20180817 Printed 05 09 2018 Doc Nr PUB 5450687 000 00 ...

Reviews: