1 Introduction

1.1 Scope of Performance

In automation technology it is becoming obvious that Ethernet with the TCP/IP
protocol from the classical conductor field is moving continuously forward into
the fieldbus region. Although attempts are being made to lead Ethernet up to the
individual I/O modules, yet neither all the technical aspects been satisfactorily
solved nor can it be realized with a sufficient effort.

This trend is further strengthened by the requirement for unbroken communicati-
on from the office world up to the individual data point in the industrial installati-
on. Remote maintenance via the Internet is the buzzword now.

This is where our fieldbus  Gateway  PKV 50  comes into its own. It connects the
Internet-/Ethernet world with the harsh industrial environment of established
fieldbus technology.

It consists of a Master interface connection, which, by means of one of the stan-
dardized fieldbus systems, exchanges data between the connected I/O devices and
the internal process data memory. This data can be accessed for reading and wri-
ting by means of  TCP/IP telegrams.

The Microsoft Windows CE operating system is used on the Gateway. Here,
further tasks, such as SoftPLCs, are simply added in order to incorporate extensi-
ons of the functions. The development system is economical to build up and
many engineers are familiar with the development environment. All our inter-
faces are open so that the experienced user can also bring his own applications in-
to use on the Gateway.

A further highlight is the integrated Web-Server. HTML pages can be created on
a corresponding editor and then loaded on to the Gateway. Process data can be
linked via Java Applets. All that is still needed to access the data of the Gateway
via the Internet is a Web Browser such as for example, Microsoft Explorer or
Netscape Navigator. 

The configuration of the Gateways is carried out locally with our  SyCon System
Configurator via the RS232C serial diagnostic interface or remotely via TCP/IP.

The PKV 50 fieldbus Gateway is now offered for the most important fieldbus
systems.

Customer-specific solutions can be implemented by us or by the customer
himself.

Introduction

4

Copyright * Hilscher Gesellschaft für Systemautomation mbH * De:PKV50#2EN

Summary of Contents for PKV 50 Series

Page 1: ...esellschaft f r Systemautomation mbH Rheinstra e 15 D 65795 Hattersheim Germany Tel 49 6190 9907 0 Fax 49 6190 9907 50 Sales 49 6190 9907 0 Hotline and Support 49 6190 9907 99 Sales email sales hilsch...

Page 2: ...ing Guarantee claims shall be limited to the right to require rectification Liability for any damages which may have arisen from the use of this appliance or its documentation shall be limited to case...

Page 3: ...tting the IP Address 11 3 1 5 Starting Applications 11 3 2 Connecting the Supply Voltage X2 12 3 3 Interfaces 13 3 3 1 Ethernet Interface X4 13 3 3 2 Fieldbus Interface X6 14 3 3 2 1 PROFIBUS Interfac...

Page 4: ...can be accessed for reading and wri ting by means of TCP IP telegrams The Microsoft Windows CE operating system is used on the Gateway Here further tasks such as SoftPLCs are simply added in order to...

Page 5: ...er available but only uses the servi ces of the next lower layer itself The Gateway fulfills this structure The Gateway in the ISO OSI reference model T a s k IP Realtime OS Tasks for Fieldbus Etherne...

Page 6: ...ating voltage is switched off The proper function of the Gateway and its internal operating voltage is monito red by a Watchdog circuit In the case of error it triggers a Reset at the processor The in...

Page 7: ...to point con nection with a crossed cable or for example via a Hub with commercial Ethernet cables The Gateway is supplied with a default IP address see information sheet Configuration dialog for the...

Page 8: ...ed process is stopped In order to transfer a new file select the File Copy to PKV menu or activate the Copy to PKV button Select the file to be loaded in the dialog that appears now Dialog for loading...

Page 9: ...of the file that is to be loaded can be entered directly into the Sour ce PKV field or the contents of the FLASH can be viewed via the button and a file can be selected The target place and target na...

Page 10: ...ter building up the connection successfully A list of files that are permanently stored in the User FLASH memory is displayed now Now previously selected files can be deleted with the Delete button G...

Page 11: ...sful it will be displayed A request for restar ting the Gateway will appear Please note that the newly allocated IP address is only valid after a restart of the Gateway 3 1 5 Starting Applications App...

Page 12: ...t The supply voltage must be led to ground It is connected by means of a plug in screwed clamp Use is made of a 3 pin COMBICON plug from the PHOENIX company MSTB 2 5 3 ST 5 08 Connection Symbol Signal...

Page 13: ...hird interface X4 The third interface is used for connection to a 10 100BaseT network 3 3 1 Ethernet Interface X4 Connection Input Output Signal designation 1 Output TXDE 2 Output TXDE 3 Input RXDE 6...

Page 14: ...control signal 5 DGND Data reference potential Pin assignment of the PKV50 DPM at the plug X6 3 3 2 2 CAN Bus Interface for PKV 50 COM PKV 50 DNM Connector Input Output Signal designation Signal Conne...

Page 15: ...4 and 8 of the D Sub plug The transfer between Host PC and Gateway is at 9 600 Baud and the following data format 8 Data bits 1 Stop bit and even parity The 3964R procedure is utili zed as transfer pr...

Page 16: ...rly and the further processing of the program is abor ted If no fieldbus Firmware is loaded on the Gateway then the Bootstraploader shows this by a cyclical flashing of the RDY LED in a 1 second rhyth...

Page 17: ...rier rail TS35 according to DIN EN 50022 The mechanical dimensions and the allocation of the pins are shown in the following figures Front view with pin arrangement on the Gateway Side view of the Gat...

Page 18: ...ud PKV 50 DNM Serial interface non isolated RS232C Diagnostic interface LED displays Operation and communication readiness of the Gate way error on the serial interface or freely programma ble by the...

Reviews: