Descriptions
16/83
2.6.2
X500 – Ethernet connectors
Two RJ45 jack Ethernet connectors
X500
. For identifying the connectors on
the board, see position
(28)
for channel 0 and position
(33)
for channel 1 in
section
Positions of interfaces and operating elements
Ethernet
Pin
Signal
Description
1
TX+
Transmit data positive
2
TX–
Transmit data negative
3
RX+
Receive data positive
4
Term 1
Connected and terminated to FE via RC
combination*
5
Term 1
6
RX–
Receive data negative
7
Term 2
Connected and terminated to FE via RC
combination*
8
Term 2
* Bob Smith Termination
Table 11: Ethernet RJ45 pin assignment
For a description of the LEDs of the Ethernet connector, see section
2.6.3
X601 – SPM host interface connector via SQI/SPI
Pin header
X601
for connecting a host to the Serial Dual-Port Memory
(SPM) of the netX via SQI/SPI. For identifying the connector on the board,
see position
(5)
in section
Positions of interfaces and operating
X601
Pin
Signal
SQI0
SPI0
1
SIRQ#
SIRQ#
2
+3V3
+3V3
3
DIRQ#
DIRQ#
4
GND
GND
5
CLK
CLK
6
GND
GND
7
CS#
CS#
8
GND
GND
9
SIO0
MOSI
10
GND
GND
11
SIO1
MISO
12
GND
GND
13
SIO2
Not connected
14
GND
GND
15
SIO3
Not connected
18
GND
GND
Table 12: Pin assignments X601
NXHX 90-MC | Device description
DOC200602HW01EN | Revision 1 | English | 2021-02 | Released | Public
© Hilscher 2021