LEDs
75/90
10 LEDs
10.1 LEDs NANL-B500G-RE
10.1.1
SYS, STA0, STA1, I/O, LINK and RX (Front side)
Interactive operating mode and Autonomous operating mode
LED
Color
State
Meaning
Front side NANL-B500G-RE
SYS
green
On
Operating system running
yellow
Flashing cyclic at
1Hz
Device indicates boot error.
yellow
On
Device starts (is in boot process).
off
Off
Power supply for the device is missing or hardware defect
STA0
green
On
Capturing process active, with or without connected
USB memory device, live dump mode
green
Flashing cyclic at
1 Hz
Autonomous operating mode only:
Capturing process active, snapshot mode
green
orange
Flashing cyclic at
1 Hz
Autonomous operating mode only:
Capturing process active, snapshot mode;
No restart of the network has been detected yet.
green
Flashing cyclic at
5 Hz
Autonomous operating mode only:
Snapshot mode available
Snapshot mode: At least one snapshot was saved.
green
orange
Flashing cyclic
green at 5 Hz
(and orange flash
every 500 ms)
Autonomous operating mode only:
Snapshot mode available
Snapshot mode: At least one snapshot was saved.
No restart of the network has been detected yet.
orange
Flashing cyclic at
1 Hz
Autonomous operating mode only:
USB memory device connected,
capturing process inactive, snapshot mode
orange
On
Autonomous operating mode only:
USB memory device connected,
capturing process inactive, live dump mode
red
On
Capturing process is inactive, with or without
USB memory device connected or USB memory device is not compatible
or defective.
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public
© Hilscher 2007-2019