Installing the hardware
21/55
4.6
Hints for problem solving
In case of an error or malfunction during operation of your PC card cifX,
observe the following troubleshooting instructions:
General
Ø
Check that the requirements for operation of the PC card are met
according to the information provided in this user manual.
SYS and COM status LEDs
You can troubleshoot the system by checking the behavior of the LEDs.
·
The SYS LED on the device indicates the general device status and can
permanently light yellow or green, or blinking yellow/green.
·
The COM LEDs on the detached network interface indicate the status of
the device communication and can be switched on or flash cyclically or
acyclically, green or red (or orange = red/green simultaneously).
If the SYS LED lights static green and the communication status LEDs light
as shown in the table below, the PC card is in the "operation" state, the
Master is exchanging data with the connected Slaves and communication
is running touble-free.
LED
EtherCAT Slave
EtherNet/IP Adapter
PROFINET IO-Device
COM 0
RUN
(green)
MS
(green)
SF
(off)
COM 1
ERR
(off)
NS
(green)
BF
(off)
Table 13: Behaviour of the communication status LEDs in "in operation" status
Ethernet LEDs
Ø
Check the status of the Ethernet LEDs (LINK or L/A) to see if there is a
connection to the Ethernet.
Cable
Ø
Check that the pin assignment of the cable used to connect the PC card
(Slave) to the PC card (Master) is correct.
Detailed descriptions of the behavior of the LEDs can be found in
the chapter on LEDs in this manual. Information about the device
diagnostics and its functions can be found in the user manual of the
configuration software for your device.
CIFX M223090AE Real-Time Ethernet | Hardware description and installation
DOC190704UM02EN | Revision 2 | English | 2020-06 | Released | Public
© Hilscher 2020