Hilmerson Safety Safety Rail System Installation Instructions Manual Download Page 4

*Approved fall protection must be utilized while installing bases and guardrails where fall hazards exist. 

 

 

 

 

 

 

 

 

 

Component Identification 

   

 

 

 
 

 
 

 
 

 
 

 

 
 

 

 

 
 

 
 

 
 

 
 

 
 

 

 
 

 
 

 
 

 
 

 
 

 
 

  A1 

HLM-

GR10G 

Rail Panel 

 10 ft: 

1 ⅝” O.D.  x

 

Galvanized 13 gage 

tube with 11 gauge 
toe board 

 

  A2 

HLM-GR5G  Rail Panel 

 5 ft: 

1 ⅝” O.D.  x

 

Galvanized 13 gage 

tube with 11 gauge 
toe board 

  B1 

HLM-

GR10NTG 

Rail Panel 

 10 ft: 

1 ⅝” O.D.  x

 

Galvanized 13 gage 
tube 

 

  B2 

HLM-

GR5NTG 

Rail Panel 

 5 ft: 

1 ⅝” O.D.  x

 

Galvanized 13 gage 

tube 
 

 

HLM-

GR9NTG 

Rail Panel 

 5.5 ft

9ft: 

(Adjustable)  

1 ⅝” O.D.  x

 

Galvanized 13 gage 

tube 

 
 

 
 

 
 

 

Warning:

  It is recommended that a competent person approve and oversee the installation of this 

system. 

The Hilmerson Safety Rail System™ is an engineered system.  Incorrect installation, 

unapproved use of other manufacturer

s’ 

components, or the failure to follow these instructions may 

put workers at risk by weakening the design of the system, causing a system failure, and potentially 
leading to serious injury or death.

  

 

Tools Needed for Installation:

  Drill and ½ inch concrete drill bit, ¾ inch socket                                                

Compatible with Most Construction Debris Netting. 

Call for specific wind load capacities.            

A2 

A1 

B2 

B1 

Summary of Contents for Safety Rail System

Page 1: ...merson Safety Rail System poses a threat to safety and health and may result in death or serious injury to installers users and or third parties Hilmerson Safety and our manufacturer expressly disclai...

Page 2: ...deck that changes location as additional floor roof or deck or formwork sections are placed or constructed A leading edge is considered an unprotected side and edge OUTRIGGER RETURN A 5 ft or 10 ft gu...

Page 3: ...nstalled on is capable of supporting the product and personnel installing it A complete assessment of the entire surrounding areas should be made to determine if the walking and working surfaces have...

Page 4: ...nel 5 5 ft 9ft Adjustable 1 O D x Galvanized 13 gage tube Warning It is recommended that a competent person approve and oversee the installation of this system The Hilmerson Safety Rail System is an e...

Page 5: ...ade 50 Steel Galvanized E HLM GRBPG Penetrating Anchored Base Plate ASTM A572 Grade 50 Steel Galvanized F HLM GRBPDL Weighted Base Dolly 1 O D x Galvanized 13 gage tube Powder Coated G HLM RS3G 22 34...

Page 6: ...he desired protection layout before beginning the installation process 3 All guardrail layouts must be designed or approved by a competent person 4 When using penetrating anchored base plates anchor b...

Page 7: ...gth of f c 3 000 psi normal weight cracked concrete Non penetrating weighted bases are recommended for use on post tension decks or other surfaces where you can t penetrate 2 Pre drill a diameter hole...

Page 8: ...n 418072 through the top of the base plate and into the pre drilled hole according to Hilti p n 418072 x 3 KWIK HUS EZ KH EZ installation requirements 2 Tighten the anchor bolt until it is seated on...

Page 9: ...to set up guardrail protection on a wide variety of surfaces but shall be no closer than 18 inches from the leading edge requiring protection unless there is an elevated parapet wall 2 Install only o...

Page 10: ...hazards exist Installing Guardrail Panels 1 To install guardrail panels on either type of baseplate simply remove a guardrail panel from the mobile cart and seat on the base plate post 2 When seating...

Page 11: ...stalling Guardrail Panels 3 Install a gravity locking pin through the base plate post and guardrail panel making sure that the loop on the pin falls into the locked position 4 When installing guardrai...

Page 12: ...return guardrail panels and weighted bases are required to be installed perpendicular to the leading edge at the end of each protection run to provide required counterweight 2 Upon completion of insta...

Page 13: ...re accurate to a degree consistent with current practice s Hilmerson Safety Services Inc and its affiliates do not assume responsibility for errors or oversights that may result from the use of the in...