![Hillyard TRIDENT T26SC PLUS Service Manual Download Page 44](http://html1.mh-extra.com/html/hillyard/trident-t26sc-plus/trident-t26sc-plus_service-manual_2134723044.webp)
Actuators Parameters
Parameter
Default
Min
÷
Max
Description
Actuator - Brushes
Timeout # sec.
10
0
÷
30
Max working time of the brushdeck Actuator.
Actuator - Brushes
Overload Level # Amp.
5.0
2.0
÷
10.0
Brushdeck Actuator Rated current; with T Nom manages the
amperometric protection (alarm + stop Actuator).
Actuator - Brushes
Overload Time # sec.
2.0
0.1
÷
5.0
Brushdeck Actuator Rated Timer; with I Nom manages the
amperometric protection (alarm + stop Actuator).
Actuator - Squeegee
Timeout # sec.
5
0
÷
30
Max working time of the Squeegee Actuator.
Actuator - Squeegee
Overload Level # Amp.
5.0
2.0
÷
10.0
Squeegee Actuator Rated current; with T Nom manages the
amperometric protection (alarm + stop Actuator).
Actuator - Squeegee
Overload Time # sec.
2.0
0.1
÷
5.0
Squeegee Actuator Rated Timer; with I Nom manages the am-
perometric protection (alarm + stop Actuator).
Actuator - Squeegee
Traction reverse Delay # sec.
1.0
0.0
÷
10.0
With reverse gear, Time after which the Actuator lifts the
Squeegee.
Traction Parameters
Parameter
Default
Min
÷
Max
Description
Traction - Speed Sets
Acceleration Ramp 1 - # sec.
3.0
0.5
÷
5.0
In Transfer Mode, Time to reach the max speed.
Traction - Speed Sets
Deceleration Ramp 1 - # sec.
2.0
0.3
÷
5.0
When the traction lever is released, the time necessary to stop
the machine.
Traction - Speed Sets
Reverse Ramp 1 - # sec.
2.0
0.3
÷
5.0
In Transfer Mode, Time to pass from forward way to reverse
way and viceversa.
Traction - Speed Sets
Forward Max Speed # %
100
50
÷
100
Maximum speed in forward way (in % of the max reachable
speed).
Traction - Speed Sets
Backward Max Speed # %
50
10
÷
100
Maximum speed in reverse way (in % of the forward way set
speed).
Traction - Speed Sets
Minimum Speed # %
0
0
÷
50
Speed at the minimum pressure of the traction lever.
Traction - Speed Sets
Mode2 Speed # %
70
10
÷
100
In Working Mode, Maximum speed in forward way (in % of the
max reachable speed).
Traction - Speed Sets
Speed level #1 %
50
0
÷
100
Max forward speed, Level 1.
Traction - Speed Sets
Speed level #2 %
75
0
÷
100
Max forward speed, Level 2.
Traction - Speed Sets
Speed level #3 %
100
0
÷
100
Max forward speed, Level 3.
Traction - Speed Ref
Signal Min Position # V
0.7
0.0
÷
10.0
Minimum voltage of the released potentiometer.
Traction - Speed Ref
Signal Max Position # V
3.3
0.0
÷
15.0
Max voltage of the active potentiometer.
Traction - Speed Ref
Signal Dead Band # mV
50
0
÷
500
Potentiometer dead band