Rev #
Rev Date:
Revision Description:
ALL MEASUREMENTS ARE TAKEN PER
ASHRAE-72-2005 SPECIFICATIONS.
Hillphoenix
REFRIGERATED DISPLAY CASES FOR SALE IN THE
UNITED STATES MEET OR EXCEED DEPARTMENT OF
ENERGY 2017 REQUIREMENTS.
COMPONENT
OHMA-NRG
High Multi-Deck Self-Contained Merchandiser
6' (Meat)
OHMA-NRG
1
10-27-17
DOE 2017
SYSTEM REQUIREMENTS
Volts
Phase Frequency (Hz)
Plug Style
Cord Length
208
1
60
NEMA L14-30P
120"
LIGHTING DATA
Lights
Per Row
Light
Length
Clearvoyant v4 LED Lighting
(Per Lifght Row)
Standard Power
(Cornice or Shelf)
High Power
(Cornice Only)
120 Volts
120 Volts
Amps
Watts
Amps
Watts
2
3'
0.08
9.4
0.20
23.8
GUIDELINES AND CONTROL SETTINGS
24 hour Energy
Usage
Suction Pressure @ Case
Outlet (psig).
Superheat Set Point
@ Bulb
Discharge
Air
Discharge
Air Velocity
47.6 (kWh)
52-54
6-8 °F
30.0 °F
210 FPM
CONDENSING UNIT DATA
Volts Phase
Frequency
(Hz)
Horsepower
Running Load
Amps (RLA)
(Amps)
Locked Rotor
Amps (LRA)
(Amps)
Refrigerant
Lbs. of
Refrigerant
208
1
60
1 1/4
9.2
54.0
R404A
5.5
DEFROST CONTROLS
Defrosts
Per Day
Timed-Off Defrost
Fail-Safe
(Min)
Termination
Temp
6
30 (Min)
42 °F
•
P111801H
Summary of Contents for OHMA-NRG
Page 20: ...WIRING DIAGRAM B2 P111801H ...
Page 21: ...SET POINTS C1 P111801H ...
Page 23: ...DIXELL CASE CONTROLLER E1 P111801H ...
Page 27: ...Seismic Bracket 5 F2 P111801H ...
Page 28: ...Seismic Bracket 7 F3 P111801H ...
Page 29: ...Seismic Bracket 11 F4 P111801H ...
Page 30: ...Seismic Bracket 15 F5 P111801H ...
Page 32: ...INTERNAL CASE COMPONENTS LAYOUT H1 P111801H ...