USE 

AND

MAINTENANCE

POSITIVE DRAIN OFF

CASE CLEANING

Case is designed to facilitate cleaning.  There is a wide

radius formed on the front and back of the inside bottom
that helps accelerate liquid flow and eliminates difficult-to-
clean sharp corners.  All surfaces pitch to a deep-drawn
drain trough that angles toward the front and center of case
where the waste outlet is located for easy access.

The coil is covered to keep food fluids from entering, but

the cover lifts up easily when coil cleaning is desired.  The
single piece fan plenum lifts up for cleaning, exposing a
major portion of the inside bottom of the tank.  Make cer-
tain fan plenum is properly closed after cleaning to avoid
air leaks.  Front return air grills snap out for cleaning; no
fasteners are used.

In order to keep the unit running at peak design

efficiency the air intake grill and the condenser coil should
be cleaned at least once a month. 

SINGLE PIECE FAN PLENUM LIFT UP

SINGLE PIECE FAN
PLENUM  SWINGS
UP FOR EASY
CLEANING

PLENUM

COIL

CLEAN HONEYCOMB

HONEYCOMB

LOOSEN
SCREW

SLIDE REAR HONEYCOMB
RETAINER BACK AND
REMOVE HONEYCOMB

DANGER

Electrical Shock Hazard 

Always disconnect power to case

when servicing or cleaning. 

HIGH

PRESSURE

CLEANING PROCEDURES

• A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency,  and 

avoid the corrosive action of food fluids on metal parts that are left on for long periods of time.  We recommend cleaning once 
a week.

• To avoid shock hazard, be sure all electrical power is turned off before cleaning.  In some installations, more than one

disconnect switch may have to be turned off to completely de-energize the case.

• Check waste outlet to insure it is not clogged before starting the cleaning process and avoid introducing water faster than the 

case drain can carry it away.

• Avoid spraying cleaning solutions directly on fans or electrical connections.

• Provide a temporary separator between those cases which are being cleaned and those which are not.

• Allow cases to be turned off long enough to clean any frost or ice from coil and flue areas.

• Remove and clean discharge honeycomb.   You may need to use spray detergent and a soft, long bristle brush.

• Use mild detergent and warm water.  When necessary, water and baking soda solution will help remove case odors.  Avoid 

abrasive scouring powders or pads.

• Remove front panels and clean underneath the case with a broom and a long handled mop.  Instructions for removing the 

front panels can be found on page 6 of this manual.

• Use warm water and a disinfecting cleaning solution when cleaning underneath the cases.  

Summary of Contents for 05DMA

Page 1: ...DAIRY DELI PRODUCE C A S E S MODEL O5DMA HANDBOOK INSTALLATION OPERATION P056442G Rev 10 12 04...

Page 2: ...fore cleaning case HIGH PRESSURE HIGH PRESSURE WARNING Some surfaces may be hot when case is in operation HIGH PRESSURE WARNING Always turn off power to lights before servicing HIGH PRESSURE DANGER El...

Page 3: ...o make it easier to read and to help you get the most from this innovative new design When you follow the instructions you should expect remarkable performance attractive fits and finish and long case...

Page 4: ......

Page 5: ...S PAGE 7 Operational descriptions of the refrigeration components PLUMBING PAGE 8 Information on drain connections ELECTRICAL HOOKUP CONTROL SETTINGS AND WIRING DIAGRAMS PAGES 9 16 Complete informatio...

Page 6: ...1109 APPARENT DAMAGE A claim for obvious damage must be noted on the freight bill or express receipt and signed by the carriers agent otherwise the carrier may refuse the claim CONCEALED DAMAGE If dam...

Page 7: ...13 1 cm COIL PLENUM 6 13 16 in 17 2 cm 43 1 4 in 109 9 cm 32 in 81 3 cm 59 in 149 9 cm 3rd ROW LIGHT OPTIONAL 9 75 MIRROR OPTIONAL 13 MIRROR OPTIONAL 14 1 2 in 36 9 cm 18 11 16 in 47 5 cm 55 13 16 in...

Page 8: ...ERS MAY BE DISCARDED ROLL OUT OF TRUCK When there is a truck level delivery dock cases may be rolled directly from the truck to the store floor CAUTION If skid boards are required to unload cases cast...

Page 9: ...rail See illustration 1 below for details When installing the upper kickplate retainer make sure it is placed behind the front panel lip as shown in illustration 1 below The end kickplates which are...

Page 10: ...e expansion valve and other controls are located on the left hand side of the case and are accessible without lifting the fan plenum The controls cluster may be reached by lifting only the left hand d...

Page 11: ...at transfer Filter Drier A device installed on the liquid line of a refrigeration system that removes water and other impurities from the refrigerant in the lines during initial start up Receiver The...

Page 12: ...e issues arise care should be given to assure that all connections are water tight and sealed with the appropriate PVC or ABS cement The case run off is channeled to a drain pan located underneath the...

Page 13: ...nd not as a power supply for peripheral equipment FIELD CONNECTION JUNCTION BOX DRAIN PUMP RECEPTACLE DANGER Electrical Shock Hazard Always disconnect power to case when servicing or cleaning HIGH PRE...

Page 14: ...reflectors may be easily removed be removing a several screws along the length of the reflector See below 1 Remove lamps by pulling down at both ends 2 Remove screws along length of the reflector 3 R...

Page 15: ...s dd Maximum Defrost Duration 1 to 99 min dC Dripping Time After Defrost 0 to 99 min dU Initial Defrost Interval time before first defrost after startup 0 to 99 min dP Defrost Display 0 displays last...

Page 16: ...test Cycle power to resume operation Press the Up and the Down buttons in sequence and hold for 5 seconds To Initiate Self Test Press and the Enter and Up buttons in sequence and hold for five seconds...

Page 17: ...lished by com paring the temperature reading of the case temperature probe against the temperature setpoint The compressor out put is used to control the temperature If the temperature is above the te...

Page 18: ...r that setpoint will be displayed 4 Press the Compressor or Defrost key to change the value 5 Press the Alarm key to go back to the code At this point you must press the Alarm key to accept the change...

Page 19: ...d defrost dd Drip time 0 15 min d8 Alarm delay after defrost 0 15 hours d Defrost probe reading read only C F AL Low temperature alarm differential subtract this value from the temperature 0 127 C F s...

Page 20: ...16 WIRING DIAGRAMS MODEL O5DMA...

Page 21: ...Fail safe min 4 Termination Temp F Defrost Controls All measurements are taken per CRMA specifications Medium Temperature Defrost Schedule No Per Day Hours 1 12 midnight 2 12 am 12 pm 3 6 am 2 pm 10 p...

Page 22: ...ess to the probe can be gained by removing the lower rear baffle The temperature control probe is located behind the 3 1 2 plug button in the top flue panel also shown in the diagram below Both of the...

Page 23: ...not overload the food product display so that it impinges on the air flow pattern DISCHARGE 1 LOAD LIMIT 2 AIR FLOW 3 RETURN AIR GRILL 4 MODEL O5DMA Overloading will cause malfunction and the loss of...

Page 24: ...RE CLEANING PROCEDURES A periodic cleaning schedule should be established to maintain proper sanitation insure maximum operating efficiency and avoid the corrosive action of food fluids on metal parts...

Page 25: ...ch be maintained as specified Do not attempt a field modification by altering the blades Fan motors may be changed with an easy two step process without lifting up the plenum thereby avoiding the nece...

Page 26: ...E09 E11 E10 E20 50 E06 E07 22 PARTS ORDERING 11 24 9 1 26 2 17 19 22 15 12 13 20 25 51 3 88 87 38 82 E19 81 36 86...

Page 27: ...or Unlighted Painted White Custom Color or Stainless 24 J Rail for Kickplate 25 Top Flue Panel Painted White Custom Color or Stainless 26 Front Panel Curved Shown or Flat Painted Custom Color 36 Plug...

Page 28: ...of the case on which the part is used Length of part if applicable I E 4 6 8 Color of part if painted or color of polymer part Whether part is for left hand or right hand application Whether shelves...

Page 29: ...25 NOTES...

Page 30: ...26 NOTES...

Page 31: ...sales tax or upgrading 5 When the operation is impaired due to improper installation 6 When installation and startup forms are not properly complete or returned within two weeks after startup THIS PLA...

Page 32: ...cleaning cases the following must be performed PRIOR to cleaning To avoid electrical shock be sure all electric power is turned off before cleaning In some installations more than one switch may have...

Reviews: