Apart from using good equipment, good sound comes from using it correctly. Level 
setting mistakes are one of the common reasons why even good equipment may not 
perform as desired. For setting levels, please be reminded that two guidelines need to 
be followed: 
 

  Avoid distortion by leaving some headroom. Never overrun any audio-

equipment’s inputs. Level meters and displays allow you to make sure that 
signals do not enter critical levels.   

 

Avoid unnecessary amplification by using as little attenuation as possible. For 
example, if you turn down the input gain of a mixer to minimum, and then 
increase the main output of the mixer to maximum to drive your amplifier 
properly, you will create unnecessary noise, as you first dispose of some 
already existing signal level, and then later apply amplification (tainted with 
noise) to make it up.  

 
Obviously, these two requirements are marking a levelling window that the operator 
must match to achieve a good sound with as little distortion and noise as possible.  
 
 

 

DANGER

: Excessive volume levels on headphones or other sound 

systems may cause hearing damage. Always turn the volume control to 
minimum when you switch the unit on, and do not exceed healthy 
listening levels.  

 

 

Maintenance and warranty

 

 
While we have chosen the best components to make this product as rugged and 
reliable as possible, some parts in audio products (potentiometers, faders, switches) 
are subject to wear which is a matter of operation cycles, and not of time. While 
providing a full time-based warranty according to the country’s of purchase 
requirements on the function of the electronic circuitry, we hence have to limit the 
warranty on such electro-mechanical parts to 90 days from the date of purchase.  
 
In many cases, malfunction of electro-mechanical parts occurs due to dust 
contamination, which may require cleaning of such parts. As the inside of such parts is 
not accessible, a common practice is to use cleaning fluids in the shape of sprays. 
Please be reminded that many of such fluids contain chemicals which may wash away 
the dust but at the same time corrode or damage contact surface and may cause 
cosmetic damage to other parts. We hence explicitly exclude any claims for exchange 
of damaged part due to mechanical or chemical impact.   
 
Without liability, we recommend CaiLube MCL fader cleaner and lubricant available 
from CAIG Laboratories if the need of cleaning for electro-mechanical parts occurs.  
 

User Manual: ZPR4620

 

6+2 Channel Rack Zoning Mixer

     

 

 

 

 

V2.00 (04-2013) © Hill Audio                                                                                                                              

5

 

 

Unpacking

 

 
Please check that the box contains the following items: 
 
Main parts: 

 

1 pcs.   ZPR4620 main unit 
1 pcs.   Mains cable 
1 pcs.   Operation manual 

 
If any part is missing, please contact your dealer immediately for replacement. 

 

 

 

Warning:

 After unpacking, and before plugging the AC cord in the wall 

outlet, check whether the AC mains voltage and frequency is the same 
as this product is specified for (see rear panel of product). Whenever 
the specified voltage or your AC plug should not match the local 
conditions, do NOT plug the AC cord into the wall outlet and contact 
you dealer immediately. 
 

 

 

Back Panel  

 

 

 

 

1.  AC inlet and fuse holder. Use the supplied AC cord to connect the unit to AC 

mains. Make sure voltage and frequency stated on the unit comply with your 
local AC supply. The fuse can be accessed by the small drawer at the AC 
inlet. To change the fuse, unplug the AC cord first, pull out the fuse drawer 
and replace the fuse ONLY with a fuse of SAME voltage and rating. If the fuse 
blows again after replacement, hand over the unit to qualified service 
personnel.  

2.  Stereo Master output. This is a balanced stereo XLR output carrying the main 

output signal controlled by (36). 

3.  Stereo Master output. This is an unbalanced RCA output carrying the same 

signal as output (2).  

Summary of Contents for ZPR4620

Page 1: ...USER MANUAL ZPR4620 6 2 Channel Rack Zoning Mixer ENGLISH Page 2 15 RevA 04 2013 Order code 12 020 0293 80200 1 01...

Page 2: ...ice before use Warning Read this section carefully before installing powering operating cleaning or servicing this product The following symbols are used to identify important safety information in th...

Page 3: ...the unit 5 Do not expose this unit to any dripping or splashing liquids and do not place objects filled with liquids such as vases on the unit Do not operate this unit near to open water or in high h...

Page 4: ...es no responsibility in this case Functional advice This unit is immune to the presence of electromagnetic disturbances both conducted and radiated up to a certain level Under peak conditions the unit...

Page 5: ...ction of electro mechanical parts occurs due to dust contamination which may require cleaning of such parts As the inside of such parts is not accessible a common practice is to use cleaning fluids in...

Page 6: ...y excessive force with the screw driver 13 100Hz High Pass filter for Mono zone outputs This helps to reduce the low frequency energy on outputs 8 9 which is specifically useful if a zone is used to f...

Page 7: ...pplications where apart from stereo source replay also live music is performed over the same sound system The FOH input is routed to input channel 6 and will replace the LINE6 signal once the relative...

Page 8: ...FOH input This is a TRS balanced stereo input specifically designed to allow the connection of the output of a stage mixer in order to use the connected sound system for the replay of the stage mixer...