![Hill Audio Andante SMA-1020 User Manual Download Page 4](http://html1.mh-extra.com/html/hill-audio/andante-sma-1020/andante-sma-1020_user-manual_2134094004.webp)
DANGER - risk of injury: Flown installation requires extensive experience, like calculating
working load limits, knowledge of installation materials, and periodic safety inspection of all
installation material and the flown product. If you lack such qualifications, do not attempt
the installation yourself. Improper installation can result in injury of people.
PAGE 3
USER MANUAL - ANDANTE ACTIVE SPEAKERS
B3. Suspended from ceiling or truss (“Flown” installation).
As a preparation for flown installation, attach eyevbolts to the mounting points in the speaker cabinet
as per below drawing. In the further course of the installation, make sure that:
The product is installed out of reach of people and outside areas where persons may walk by or be
seated.
The installation area can hold a minimum point load of 10 times the device’s weight.
The installation is secured with an appropriate safety cable where necessary. Always use a certified
safety cable according to DIN56927 that can hold 12 times the weight of the device when installing
the unit. This secondary safety attachment should be installed in a way that no part of the installation
can drop more than 20cm if the main attachment fails.
The installation place is free from unwanted persons during installation, de-installation or servicing.
The safety-relating and machine-technical installations are approved by an expert before using
them for the first time.
The installation is re-inspected every year.
The cooling requirements are met (if any). Note that warm air is ascending, making the area below
a rooms’ ceiling potentially warmer than lower locations.
SMA1520
5xM10
2xBottom
2xTop
1xRear
SMA1220
4xM10
2xBottom
2xTop
SMA1020
2xM8
2xBottom
Summary of Contents for Andante SMA-1020
Page 1: ...RevA 06 2013...