IR Speed Dome Installation Manual
16
1.3.2 Baud Rate Settings
Positions 1-3 of SW2 are for baud rate settings. Set “ON” state for each position for values
“100”,”010” and “110”, representing 2400bps, 4800bps and 9600bps respectively. Please see below
table of baud rate setting pattern.
Note:
For rates out of this range, default value 2400bps will be saved alternatively.
DIP Switch SW2-Baud Rate Settings
Baud Rate
Positions1-3 Settings
1
2
3
2400
ON
1
2
3
4
5
6
7
8
SW2
ON
OFF
OFF
4800
ON
1
2
3
4
5
6
7
8
SW2
OFF
ON
OFF
9600
ON
1
2
3
4
5
6
7
8
SW2
ON
ON
OFF
Table 1.3 Baud Rate Settings
1.3.3 Protocol Settings
Positions 4-6 of SW2 are used for protocol settings. Please Refer to Table 1.4 for details.
DIP Switch SW2-Protocol Settings
Protocol Type
Positions 4-6 Settings
4
5
6
Bosch Manchester
ON
1
2
3
4
5
6
7
8
SW2
OFF
ON
ON
AD Manchester
ON
1
2
3
4
5
6
7
8
SW2
ON
ON
ON
Self-adaptive
N/A
Table 1.4 Protocol Settings
Note:
1.
Network speed domes does not support Manchester code protocol.
2.
IR speed dome is self-adaptive to PELCO-D, PELCO-P, HIK-Code, VICON and KALATEL-32 protocols,
and network IR speed dome is self-adaptive to PELCO-P, PELCO-D and HIK-Code protocols.
Protocol settings are not applicable for both.
1.3.4 Communication Type Settings
Position 7 of SW2 is used for communication type settings. There are two types of communications,
simplex and half-duplex.
DIP Switch SW2-Communication Type Settings