HIKVISION DS-PWA32-HR Manual Download Page 2

DS-PD1-MC-WWS

Wireless Magnetic Contact

Diagram References

E N G L I S H

DS-19K00-Y/DS-PKFE-5

Wireless Keyfob

2

1

2

3

Control Panel x 1 

Battery x 1

Magnetic Door Contact x 1

Detector x 1

Keyfob  x 1

Power Adapter x 1

Screw x 4

Quick Start Guide x1

2

1

4

4

2

5

2

6

2

2

2

3

Specification

21

22

23

COPYRIGHT ©2018 Hangzhou Hikvision Digital Technology Co., Ltd. 

ALL RIGHTS RESERVED.

Any and all information, including, among others, wordings, pictures, graphs are the 

properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries 

(hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the 

Manual”) cannot be reproduced, changed, translated, or distributed, partially or wholly, 

by any means, without the prior written permission of Hikvision. Unless otherwise 

stipulated, Hikvision does not make any warranties, guarantees or representations, 

express or implied, regarding to the Manual.

About this Manual

This Manual is applicable to the Axiom Security Control Panel Kit.

The Manual includes instructions for using and managing the product. Pictures, charts, 

images and all other information hereinafter are for description and explanation only. The 

information contained in the Manual is subject to change, without notice, due to firmware 

updates or other reasons. Please find the latest version in the company website 

(http://overseas.hikvision.com/en/). 

Please use this user manual under the guidance of professionals.

                               Trademarks Acknowledgement and other Hikvision’s trademarks and 

logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos 

mentioned below are the properties of their respective owners.

Components

Product Information

3

1

2

3

4

1mm

This product and - if applicable - the supplied accessories too 

are marked with "CE" and comply therefore with the applicable 

harmonized European standards listed under the RE Directive 

2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 

2014/35/EU,  the RoHS Directive 2011/65/EU.

1

2

3

4

Indicator

Red: Press the Key

Green: Successful Operation

Away Arming

Indicator

Disarming

Clearing Alarm

Stay Arming

Panic Alarm(Hold for 2s)

Formatting

1. Remove the battery.

2. Hold the Away Arming key of the keyfob, and reinstall the battery at 

the same time to power the keyfob on . The formatting is completed after 

the red LED flashes three times.

1. Dig the groove to disassemble the device. Remove the front 

and rear panel.  Remove the insulating strip to power on the 

device.

Note: Do not disassemble the device with sharps. 

2. Assemble the front panel and rear panel.  

Add Keyfob

You can add keyfob to the security control panel via the web client of the 

control panel.

1. Click System → Keyfob to enter the Keyfob Management page.

2. Click Add and press any key on the keyfob.

3. Set the keyfob parameters.

4. Click OK.

Note: If the keyfob is required to be added to wired security control panel, 

refer to the User Manual of Wired Security Control Panal for connecting 

details.

Delete Keyfob

On the Keyfob Management page, you can delete a selected keyfob or 

check multiple keyfobs and click Delete to delete in batch.

Note: You need to format the keyfob after deleting to unregister it from a 

control panel, which allows you to add the keyfob to another control 

panel.

2

1

2

2

2

3

2

4

2

5

2

6

Appearance

1

Installation

2

Registration

3

CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACED BY 

AN INCORRECT TYPE.

DISPOSE OF USED BATTERIES ACCORDING TO 

THE INSTRUCTIONS

CHEMICAL BURNING DANGER

DO NOT SWALLOW THE BATTERY

KEEP NEW AND USED BATTERIES AWAY FROM 

THE CHILDREN

Installation Datum Line on the Sensor
Installation Datum Line on the Magnetic Stick

The sensor can detect the door or window opening. When the door or window is 

open, an alarm will be triggered and it will be sent to the alarm center or mobile 

client via security control panel.

Door Magnetic Sensor Alarm: When the distance between the sensor and the 

magnetic stick is longer than 3 cm, an alarm will be triggered. The indicator will 

flash once.

Tamper Alarm: When removing the sensor, an alarm will be triggered.

Power on the security control panel. Press the function button once and then 

trigger the detector. And you can add the detector accroding to the voice prompt. 

The green LED of the detector will flash 8 times after being successfully added. 

Note: The distance between the security control panel and the detector should be less than 50 

cm. 

Register the Detector Locally

Register the Detector via APP

1. Check Signal Strength

Enter the signal checking mode by operating on the control panel.Trigger the 

detector.

Solid Green for 3 s - Strong Signal 

Solid Red for 3 s  - Weak Signal

1. Log in to the 

APP Store

 and input “Hik-Connect” to search the mobile client.

5. Log in the Hik-Connect and ap the icon “+”  at the upper-right coner of the 

Hik-Connect page to add the security control panel. You can scan the QR code on 

the device rear panel or on the package box, or input the device serial No. manually 

to add the device when the device is in the registration mode.

6. After adding the security control panel, tap the arming status icon on the right of 

the security control panel’s name to enter the Partition page.

2. Download and install Hik-Connect to your phone.

3. After installing, tap        to run the client.

4. Power on the security control panel.

7. Tap the “+” icon on the Partition page to add the peripherals. 

Indicator

Alarm Detection: 

Red LED flashes.

Display Signal Strength: 

Under the signal strength checking mode: 

Solid Green for 3 s - Strong Signal 

Solid Red for 3 s - Weak Signal

TAMPER Button

-Tampering Alarm: If the detector is disassembled, an alarm will be triggered.

-Formatting: Remove the battery. Hold the TAMPER button and power the 

detector on at the same time. The red LED flashes 3 time when the formatting 

is completed.

Detector Installation

2. Install the Detector

Paste the sponge tape on the rear side of the detector.

Paste the detector on the required place.

Note: To make the TAMPER work properly, the thickness of the sponge tape 

should be no more than 1mm. 

English
Diagram Reference

Specification

1

3

2

4

Appearance

1

Detector Power On

2

4

Detector Registration

3

a

b

2. Assemble the front panel and rear panel by align ingthe Indicator groove on the 

front panel with the Indicator light pipe on the rear panel. 

1. Dig the groove to disassemble the device. Remove the front and rear panel. 

Remove the insulating strip to power on the device.

Note: Do not disassemble the device with sharps. 

3. Paste the sensor at the door or window’s edge. Make sure the 

sensor is aligned with the door or window’s edge.

4. Paste the magnetic stick at the door or window’s edge. Make sure the 

magnetic stick is aligned with the door or window’s edge.

Detector Formatted: 

Red LED flashes once.

IC Card in Special Shapes x 5

Frequency

433

/868M

Hz

M

odula

ti

on

2GFSK

Transmission Distance

800m (O

p

en Area)

Indicator

LED

1(Dual-Color)

Power Supply

Ba

tt

ery

CR123A

Tamper

Tam

p

er

Su

pp

orted

Tem

p

erature

 –10

 to 55

Humidity

10% to 90%

Dimension(W*H*D)

25 

x

 84  

x

 20.99mm

Weight

37.0g

Wireless

Materials and Environment

Frequency

433

/868M

Hz

M

odula

ti

on

2GFSK

Transmission Distance 300m (O

p

en Area)

Indicator

LED

Red: Press the Key
Green: Success

f

ul O

p

era

ti

on

Power Supply

Ba

tt

ery

CR2032 3.0V

Tem

p

erature

 –10

 to 55

Humidity

10%

~

90%

Dimension(W*H*D)

63.3*48.7*16.3mm

Weight

24.5g

Wireless

Materials and Environment

Reviews: