HIKVISION DS-PM1-I16O2-WB Manual Download Page 3

3

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

4. Install the board back.

Fix the transmitter to the wall with screws.

5. Enrollment

6. Power on the transmitter.

Enrollment completed: Flashing green for 7 times.

7. Install the shell back.

Enrollment Preparation

Log in to the APP Store, download and install the App.
Power on the security control panel.
Log in the APP and tap the icon "+". Scan the QR code or input the control panel serial No. to add the control panel.

In the APP, tap the "Enrollment Mode" button on the control panel page to make the control
panel enter the enrollment status.

1

Enroll the Peripheral Locally

2

Enroll the Peripheral with QR and serial No.

In the APP, tap the icon "+" and scan the QR code or serial No. on the peripheral.

4

6

7

5

xxxx

Device

7 Times

Summary of Contents for DS-PM1-I16O2-WB

Page 1: ...RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE OR IN SUPPORT OF HUMAN RIGHTS ABUSES IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW THE LATER PREVAILS Appearance 1 This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014 30 EU RE D...

Page 2: ...r Supply 100 to 240 VAC Power Supply EXT and EXT AUX and AUX Zone Input Z1 to Z16 and C Alarm Output NO1 NC1 and COM1 PGM1 and C1 Dry Contact C1 PGM1 a Alarm Input NO2 NC2 and COM2 PGM2 and C2 NC Detector NO Detector Tamper proof Dual Zone Series Connection Dual Zone Connection b 2 2KΩ 2 2K Ω NC NO Z C TAMPER Detector 2 2kΩ Local Zone Local Zone Security Control Panel Security Control Panel 8 2kΩ ...

Page 3: ...tion Log in to the APP Store download and install the App Power on the security control panel Log in the APP and tap the icon Scan the QR code or input the control panel serial No to add the control panel In the APP tap the Enrollment Mode button on the control panel page to make the control panel enter the enrollment status 1 Enroll the Peripheral Locally 2 Enroll the Peripheral with QR and seria...

Page 4: ...ce for indoor use shall be kept from rain and moisture Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger Do not aim the device at the sun or extra bright places A blooming or smear may occur otherwise which is not a malfunction however and affecting the endurance of sensor at the same time Improper use ...

Reviews: