Functions
You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client.
While Any of the two inputs generates an alarm event, the contact reports the alarm to the AX PRO. The LED keeps blue for 2 s.
4
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Set Up with App
8
Function
Zone Type
Stay Arm Bypass
Chime
Enable Silent Zone
Slide to green to enable the chime.
Slide to green to make the zone keep
silent while alarm is triggered.
Select the zone type of the detector.
Description
You can view the device status including temperature, signal intensity,battery level, lid, magnetic contact, external contact, etc.,on the device page.
Tap the button to enter the settings page.
Double Knock
Slide to green to make the zone alarm
with double knock.
Cross Zone
Link Camera
Magnetic Contact
External Contact1
Slide to green to bypass the zone from stay arming.
If the alarm triggered in both of the linked zones within
the set time, two alarm messages will be reported.
LED
Turn On/Off the LED.
Polling Rate
Set the interval of heartbeat.
Signal Strength Test
Enter the test mode, and view the LED indication.
Detection Zone Test
Enter the test mode, separate the contact, and start
the test with Magnet Detection Performance Table.
Zone Bypass
By pass the zone.
Link with a camera for intruder verification.
Slide to green to enable magnetic contact(Not allowed under EN).
Slide to green to enable the wired external contact 1.
External Contact2
Slide to green to enable the wired external contact 2.
Formatting
1. Remove the battery.
2. Hold the TAMPER button and power the detector on at the same time.
The red LED flashes 3 time when the formatting is completed.
Disallowed field adjustable settings: None