Specification
8
5
7
Functions
Operation Caution and Device Maintenance
- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related
regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment
installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service
center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment
installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation temperature), cold, dusty or
damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire
danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and
affecting the endurance of sensor at the same time.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of
used batteries according to the instructions provided by the battery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situation.
You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client.
While Any of the two inputs generates an alarm event, the detector reports the alarm to the AX PRO. The LED keeps blue for 2 s.
4
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Set Up with App
6
You can view the device status including temperature, signal intensity, battery level, lid, external input, etc.,on the device page.
Tap the
button to enter the settings page.
Formatting
1. Remove the battery.
2. Hold the TAMPER button and power the detector on at the same time.
The red LED flashes 3 time when the formatting is completed.
Disallowed field adjustable settings: None
Sensor
Omnidirectional electret microphone
Detection range
8m radius
Glass type
Float, Plate, Tempered, Wired, Laminated Leaded, Double glazing
Glass thickness
2.4mm to 6.4mm
Glass size
0.3m x 0.3m to 3m x 3m
External Inputs
2
Input options
Normal and Fast Sensitivity with Pulse Count
Programmable pulse count
Yes
Normal input sensitivity
300ms
Tamper protection
Front & Back
LED indicator
Blue(alarm)
Encapsulated plastic
Yes
Operating temperature
-10 °C to 55 °C (14 °F to 131 °F)
-10 °C to 40 °C (14 °F to 104 °F) Certified
Storage temperature
-20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity
10% to 90%
Installation
Wall/Ceiling mount
Dimension (H × W × D)
107.0 mm x 38.8 mm x 24.5 mm
Weight
134 g
Wireless technology
Tri-X Wireless Technology
Environment temperature Indicator
Yes
2-way wireless communication
Yes
Transmission frequency
868MHz
Frequency hopping
Multichannel transmisstion
Signal strength indicators
Yes
RF range
1.6Km (free space)
Enrolling methods
Power up, Remote ID, QR code
Battery
CR123A x 2 (included)
Standard battery life