Tri-pod Turnstile • User Manual
17
Chapter 4 Daily maintenance and trouble shooting
4.1 Maintenance
1)
General indications
The tripod turnstile should be inspected and cleaned at regular intervals in order to maintain
the components in good working order and to check for signs of wear. The following indications
refer to the installation where the average number of transits per year is equal to two million.
When the tripod turnstile is used in a dusty area, the regular interval for inspection should be
shortened. If used in the subway or the light rail station, the inspection interval is recommended
to be 6 months. The users are also encouraged to determine the interval according to their own
situation.
To avoid the risk of electric shock, always ensure that the electrical power is disconnected
before inspecting the mechanism.
2)
Component
Lock arms and solenoids (Operation to be carried out with the power supply
disconnected.): —Grease the pins of the lock arms that slide on the solenoid shaft.—Grease the
solenoid shaft and spring, and do not grease the core of the solenoid—check that the shaft/lock
arm assembly moves freely.
3)
Oil pressure of the damper
Operation should be carried out with the power supply disconnected
:
--check whether the
damper oil spills; --check whether the force exerted by the spring is enough
;
-- The force exerted
by the spring should match that exerted by the damper. Generally speaking, the former need to be
slightly more powerful.
4)
Upper positioning cam
Operation should be carried out with the power supply disconnected.—Loosen the spring of
the positioning lever.—Check the guide way in the cam is clean and not excessively worn. –check
some metal powder or the like sticks to the solenoid—Check the guide pin of the positioning lever
for excessive play.—Check the magnetic strip is perfectly attached to the edge of the cam——Refit
the cam -- adjust the spring of the positioning lever.
5)
Tripod
Operation should be carried out with the power supply disconnected. Check tightness of the
three securing the base plate to the mechanism shaft.
6)
Emergency Drop Arm Device
Clean all dust from the arm detents, the arm drop lever and the relative solenoid. Do not
lubricate these parts.
7)
Cable and Connectors
Operation should be carried out with the power supply disconnected
:
--Check that the wire connectors are firmly attached.
--Check that the terminals are fully tightened.
--Check that the insulation of the wires is in good condition and that no conductors are exposed.
Summary of Contents for DS-K3G4402 Series
Page 1: ...AA Tripod Turnstile Quick Start Guide...
Page 21: ......