DS-K260x-G Access Control System User Manual 

UM DS-K260x-G 021919NA 

33 

Installing a Door Lock that Requires an NC (Normally Closed) Relay 

Figure 14, Door Locks with NC (Normally Closed) Relays

 

Hikvision RS485 Reader DIP Switch Settings

Installing a Door Lock that Requires an NC (Normally Closed) Relay

Quick Start Guide

DS-K260X-G Access Control System Quick Setup Guide

ON

1

Address 1—Door 1 Entrance Card Reader

2

3

4

5

6

7

8

ON

1

Address 2—Door 1 Exit Card Reader

2

3

4

5

6

7

8

ON

1

Address 4—Door 2 Exit Card Reader

2

3

4

5

6

7

8

ON

1

Address 3—Door 2 Entrance Card Reader

2

3

4

5

6

7

8

ON

1

Address 5—Door 3 Entrance Card Reader

2

3

4

5

6

7

8

ON

1

Address 6—Door 3 Exit Card Reader

2

3

4

5

6

7

8

ON

1

Address 7—Door 4 Exit Card Reader

2

3

4

5

6

7

8

ON

1

Address 7—Door 4 Entrance Card Reader

2

3

4

5

6

7

8

Equipment

Wire Type

Maximum Length

Wiegand Reader

7 conductors/22AWG(shielded)

500 ft.

RS485 Reader

4 conductors/24AWG(CAT5/5E)

3000 ft.

Electric Strike

2 conductors/18AWG

500 ft.