©2022 Hikvision Canada Inc. All rights reserved. Hikvision is a registered trademark of Hikvision Digital
Technology Co., Ltd. in Canada and other countries. All other trademarks, service marks, and product or
service names are trademarks or registered trademarks of their respective owners. Product specifications
and availability are subject to change without notice.
22–050
Connect with us:
www.hikvision.ca
Support
Hikvision Canada: +1-866-200-6690
e-mail: [email protected]
Hikvision Canada Inc. (Toronto)
2355 Skymark Ave., Suite 300
Mississauga, ON L4W 4Y6
Toll Free: +1 866-200-6690
e-mail: [email protected]
HIKVISION.CA
DS-K260x-G Access Control System User Manual
UM DS-K260x-G 021919NA
33
Installing a Door Lock that Requires an NC (Normally Closed) Relay
Figure 14, Door Locks with NC (Normally Closed) Relays
Hikvision RS485 Reader DIP Switch Settings
Installing a Door Lock that Requires an NC (Normally Closed) Relay
Quick Start Guide
DS-K260X-G Access Control System Quick Setup Guide
ON
1
Address 1—Door 1 Entrance Card Reader
2
3
4
5
6
7
8
ON
1
Address 2—Door 1 Exit Card Reader
2
3
4
5
6
7
8
ON
1
Address 4—Door 2 Exit Card Reader
2
3
4
5
6
7
8
ON
1
Address 3—Door 2 Entrance Card Reader
2
3
4
5
6
7
8
ON
1
Address 5—Door 3 Entrance Card Reader
2
3
4
5
6
7
8
ON
1
Address 6—Door 3 Exit Card Reader
2
3
4
5
6
7
8
ON
1
Address 7—Door 4 Exit Card Reader
2
3
4
5
6
7
8
ON
1
Address 7—Door 4 Entrance Card Reader
2
3
4
5
6
7
8
Equipment
Wire Type
Maximum Length
Wiegand Reader
7 conductors/22AWG(shielded)
500 ft.
RS485 Reader
4 conductors/24AWG(CAT5/5E)
3000 ft.
Electric Strike
2 conductors/18AWG
500 ft.