background image

 

Title: 

DS-K1100 Series Card Readers Connect 
to DS-K2600 Series Access Controllers 
by RS-485 

Version: 

v1.0 

Date: 

6/21/2017 

Product: 

Access Control Device 

Page: 

2 of 4 

 

4.

 

Please check the rear panel of card reader and unscrew it, you could find DIP switch module;  

The No. of DIP switch from left to right is 1~8: 

 

 

 

 

 

 

 

 

 

Description of DIP Switch: 

 

Icon 

Description 

 

 

Represent 1 in binary mode 

 

 

Represent 0 in binary mode 

 

No. 

Description 

DIP Switch Status 

1~4 

Address of RS485 

1: 1 
0: 0 

Read card No. or file in card(Reserved) 

1: read file in card 

0: read card No. 

Wiegand protocol or RS-485 protocol 

1: Wiegand protocol 

0: RS-485 protocol. 

Wiegand Protocol 

(available when No. 6 is 1) 

1: Wiegand protocol of 26-bit; 
0: Wiegand protocol of 34-bit. 

Matched Resistance(Reserved) 
(available for RS-485 protocol) 

1: Enable; 

0: Disable. 

 

 

Step 1: DIP Switch 

 

Please set the DIP switch firstly before connecting the card reader, more details about the binary value of 

the card reader by setting DIP Switch to correspond with the door, please check the table below: 

DIP Switch Status 

Door 

Reader 

1000

 0000 

Door 1 

Entrance Reader 1 

0100

 0000 

Eixt Reader 2 

1100

 0000 

Door 2 

Entrance Reader 3 

0010

 0000 

Eixt Reader 4 

1010

 0000 

Door 3 

Entrance Reader 5 

0110

 0000 

Eixt Reader 6 

1110

 0000 

Door 4 

Entrance Reader 7 

0001

 0000 

Eixt Reader 8 

Reviews: