Sharpness
Sharpness determines the amount of detail an imaging
system can reproduce. You can set the Sharpness value
from 1 to 10.
Saturation
Adjust this feature to change the saturation of the color.
The value ranges from 1 to 10.
3D DNR (Digital Noise Reduction)
The 3D DNR function can decrease the noise effect,
especially when capturing moving images in poor light
conditions, and deliver more accurate and sharp image
quality. You can set the DNR value from 1 to 10.
Mirror
Off, H, V, and HV are selectable for mirror.
Off: The mirror function is disabled.
H: The image flips 180° horizontally.
V: The image flips 180° vertically.
HV: The image flips 180° both horizontally and vertically.
Defog
It is used in special environments such as the foggy or
rainy weather or in high illumination conditions, in which
the dynamic range is lower than that in the ordinary
environment and the image appears hazy.
Enable the defog function can enhance the subtle details
to display clear images.
3.3.5
Functions
In the function submenu, you can set the RS485.
RS485
Address <0>
Protocol PELCO D/P
Baud Rate <9600>
Back Save & Exit
Figure 3-6
RS485
Address: Set the Address from 0 to 255.
Protocol: PELCO D or PELCO P is self-adaptive.
Baud Rate: You can set the Baud Rate as 2400, 4800,
9600, 19200, 38400, or 115200.
3.3.6
Facroty Default
Click Iris+ to enter the submenu, and click OK to reset all
the settings to the factory default. Click Cancel to give up
the reset settings.
3.3.7
Save & Exit
Move the cursor to Save & Exit, and click Iris+ to save the
settings and exit the menu
.