Power switch 

 

Power on/off 

 

Alarm input wiring 

 

Alarm input is the connectors for external detector. When the resistor between the alarm input is 2.2k

Ω

, the alarm input won’t be 

triggered; else, the alarm input is triggered. 

 

You can find the 2.2k

Ω

  resisters with the alarm box.   

 

When the external detector is N.O (close when triggered; open when not triggered), please refer to below: 

 

When the external detector is N.C (open when triggered; close when not triggered), please refer to below: 

 

 

Alarm box side 

Step 1: 

Connect the alarm box with DVR via RS232 cable. 

Step 2: 

Connect power supply cable with alarm box and power on 

Step 3: 