![HIKVISION DeepinMind iDS-6700NXI Series User Manual Download Page 66](http://html1.mh-extra.com/html/hikvision/deepinmind-ids-6700nxi-series/deepinmind-ids-6700nxi-series_user-manual_2132235066.webp)
DeepinMind Series NVS User Manual
iDS-67 00 Deep inMind Series NVS User Manua l
65
Click
Stop Drawing
when finish drawing.
5)
Drag the slider to set the sensitivity value.
Sensitivity
: Range [1-100]. Sensitivity stands for the percentage of the body part of
an acceptable target that enters the pre-defined region.
Sensitivity = 100 – S
1
/S
T
*100
S
1
stands for the target body part that enters the pre-defined region S
T
stands for the
complete target body.
Example: if you set the value as 60, the action can be counted as an region entrance
action only when 40 percent body part enters the region.
The
Sensitivity
of the detection is supported by certain models. Refer to actual display for details.
6)
Repeat the above steps to configure other regions. Up to 4 regions can be set. You can
click
Clear
to clear all pre-defined regions.
Step 5
Click
Arming Schedule
to set the arming schedule.
Step 6
Click
Linkage Method
to select the linkage methods.
Step 7
Click
Save
.
6.2.6 Configuring Region Exiting Detection
Region exiting detection function detects people, vehicle or other objects which exit from a
pre-defined virtual region, and some certain actions can be taken when the alarm is triggered.
Step 1
Go to
Configuration > Event > Smart Event > Region Exiting Detection
.
Step 2
Check
Enable Region Exiting Detection
to enable the function.
Step 3
Select the
Target for Detection
to Human, Vehicle, or both.
Human Body
: Discard non-human body pictures and videos which are not triggered by
line crossing detection.
Vehicle:
Discard non-vehicle pictures and videos which are not triggered by line crossing
detection.