HIKVISION 2DC Series User Manual Download Page 1

 

 

 

 

 

 

 

User Manual of Cost-effective Network Camera 

 

Version 1.0 

 

 

 

 

 

Thank you for purchasing our product. If there is any question or request, please do 

not feel hesitated to contact us. 

This manual may contain several technical incorrect places or printing 

errors, and the content is subject to change without notice. The updates will be added 

to the new version of this manual. We will readily improve or update the products or 

procedures described in the manual.

Summary of Contents for 2DC Series

Page 1: ...quest please do not feel hesitated to contact us This manual may contain several technical incorrect places or printing errors and the content is subject to change without notice The updates will be a...

Page 2: ...should meet both the SELV Safety Extra Low Voltage and the Limited Power Source with AC 24V or DC 12V according to the IEC60950 1 standard Please refer to technical specifications for more details 3 D...

Page 3: ...lfunction however and affecting the endurance of CMOS at the same time 5 The CMOS may be burned out by a laser beam so when any laser equipment is on using make sure that the surface of CMOS will not...

Page 4: ...Camera Only support W series 11 3 1 2 Cable Network 12 3 2 Set Parameters through IE 13 3 3 Parameter Configuration through Client Software 15 3 4 Search and Amend IP 20 3 5 IP Camera Access WAN 22 3...

Page 5: ...t PT control Voice Talk Alarm User Management Network Function Support the complete TCP IP protocols video alarm audio data and IE browsing Minimum Illumination up to 0 4Lux F1 2 0Lux with IR High Sig...

Page 6: ...Figure 1 2 1 Forward Looking Appearance Figure1 2 2 Rearview Interface Appearance 5...

Page 7: ...nction and you can deploy the camera through the network Cancel Guard Cancel On Guard deployment and you cannot set the On Guard through the network Notice When the Menu is Open the above mentioned Se...

Page 8: ...Red Flicker 1 s Green Flicker 2 s Red Flicker 2 s Orange Flicker 2 s 1 3 Application Figure 1 3 1 Topological Graph of System 1 4 Default IP User Name and Password Default IP 192 0 0 64 User Name Admi...

Page 9: ...the venthole of the air conditioning or the lens will be dewed which results in mistiness 7 If the product does not operate properly please contact your dealer or the nearest service center Never att...

Page 10: ...l and slowly push it forward to remove the camera 2 3 Alarm output Connection There are two on off alarm inputs and one on off alarm output The following figure gives you visual illustration Figure 2...

Page 11: ...arm input output and RS 485 control line please gently press the orange Pressed Line Terminal and Plug the line into the connection hole then release the Pressed Line Terminal Notice Gently draw the l...

Page 12: ...rameters such as IP address and PPPOE through IE 2 Set the camera parameters through the client software Please make sure that the PC and network camera are connected and can ping successfully before...

Page 13: ...llustrates this 3 1 2 Cable Network Type 1 Trough the Ethernet interface access LAN In this mode the IP camera accesses the LAN trough the switch or the hub As the following figure show Type 2 Trough...

Page 14: ...Set the Security Level The default IP of the camera is 192 0 0 64 with 8000 as the default port admin as the administrator and 12345 as the password The administrator can create up to 15 separate oper...

Page 15: ...rameters Config dialog box to pop up and then set the parameters like IP address etc for your demand as Fig 3 2 4 Enter the menu by invoking the 95th pre set Select the function you want by clicking t...

Page 16: ...Remote Parameters Config 3 3 Parameter Configuration through Client Software After the installation of client software 4 01 click the client software 4 01 in Start Program client software 4 01 a mess...

Page 17: ...ick Login to enter the Preview menu as Fig 3 3 2 Fig 3 3 2 User Login Fig 3 3 3 Preview Menu Click the Configure button in Fig 3 3 4 and then right click the blank spaces in the middle Click the Creat...

Page 18: ...g 3 3 4Create Root Node Fig 3 3 5Area Properties Input the area name you can create whatever name you like and click OK as Fig 3 3 5 Then right click the area name you have just created as Fig 3 3 7 1...

Page 19: ...s dialog box will pop up as Fig 3 3 8 Input your Server Name and select HC from the Server Type option Select Normal from Register option Input your camera IP in Server IP e g 192 0 0 64 User Name adm...

Page 20: ...Fig 3 3 8Add Device Fig 3 3 9 Camera Adding Completed Click the Preview button to enter the Preview menu as Fig 3 3 10 Double click the channel name in the left tree to preview the pictures 19...

Page 21: ...cument in PC Operating System after the installation of client software 4 01 by selecting Start Program client software 4 01 3 4 Search and Amend IP Run the software of SADP in the CD ROM attached in...

Page 22: ...arch IP Tool Input the Password default password12345 and click modify then you can modify the device s IP address port and subnet mask The following fig gives illustration Fig 3 4 2 Modify Device Inf...

Page 23: ...namic IP address by then Fig 3 5 1 Dial Up with PPPoE Notice Please make sure that the ADSL Modem is powered on The camera needs to be restarted to establish the network connection after the configura...

Page 24: ...Then the server will search for all the registered network cameras and match the camera with this IP When the IP address is returned the client software will connect to the network camera to get the...

Page 25: ...ss Parameter and set the SSID NO Frequency band and Mode User can input any letter and number in the SSID NO Frequency Band is selected according to the on the spot environment and usually we recommen...

Page 26: ...ting is the same as the chapter 3 2 Enter the menu as Fig 3 2 2 preview page shows then click the Config option enter the interface as following Fig 3 6 2 Remote Configure parameter In channel configu...

Page 27: ...the menu Move the cursor to the menu you want to select by the UP and DOWN direction button and press the IRIS User will enable the function IF the current menu has submenu you will enter the submenu...

Page 28: ...e This function is linked client software s alarm parameter User can enable the deployment and the linkage mode 4 2 5 Privacy Protect When exit the menu and press the Privacy Protect on the remote con...

Page 29: ...28 item 4 2 7 Clear Clear the information of preset patrol scan and other settings 4 28 Password Notice The function is reserved currently...

Page 30: ...APPENDIX 1 PIN DEFINITION 1 UTP between the network port of camera and HUB Direct Cable 2 UTP between the network port of camera and PC Cross Cable 29...

Page 31: ...e network parameter of the router as the below figure The setting includes subnet mask and gateway 3 Set the port map in the virtual severs of Forwarding The following figure gives the illustration On...

Page 32: ...to the network camera 192 168 1 24 In this way user can visit the 192 168 1 23 through visiting the router s port 80 and 8000 Notice The port of the network camera cannot conflict with other ports Fo...

Page 33: ...peed 0 3 20 s adjustable Pan and Tilt Preset Speed 20 s RS 485 Protocols PRIVATE Code PELCO P D Self adaptive addible Scan Mode Cameras controlled by the client software or remote control can scan 170...

Page 34: ...33 Alarm Input 2 channels signal input Alarm Output 1 channel signal relay output Others Working Temperature 10 60 Power Supply 12V DC 10 Power Consumption 9W MAX Dimension mm 125 2 136 5 Weight 450g...