HikRobot SC3000 Series Quick Start Manual Download Page 5

SC3000 Series Vision Sensor Quick Start Guide 

iv 

Transportation 

 

The  product  contains  precision  optical  components  and  electronic  components.  During 
transportation,  storage  and  installation,  incorrect  operations  like  heavy  pressure  and  violent 
vibration should be avoided. Otherwise, the product may be damaged. 

 

Avoid  sudden  collision,  and  pack  the  product  with  the  accompanied  carton  and  cushioning 
material or similar package. 

Using Environment 

 

Do not touch the heat-radiating part of the device to avoid scalding. 

 

In order to reduce the risk of fire or electric shock, do not let the product get wet or damp. 

 

Do not drop objects onto the product and avoid vigorous vibration.   

 

Keep the product away from magnetic interference. 

 

Do  not  use  the  product  in  extremely  heat,  extremely  cold,  dusty  environment,  corrosive 
environment or high humidity environment. 

 

Do not aim the product lens at objects of strong light, such as the sun and incandescent lamp. 
Otherwise, the lens may be damaged. 

 

The product should be stored in dry environment without corrosive gas. Avoid placing the product 
in direct sunlight and poorly ventilated locations, or near heat sources such as heater or heating 
(ignoring this warning may lead to fire hazards). 

 

Do not operate in explosive environment. 

 

Keep  the  surrounding  area  well  ventilated  to  avoid  heat  accumulation.  Do  not  contact  the 
radiator directly to avoid scald. 

Electrostatic Protection 

 

Remove all conductive objects (such as jewelry, watch, etc.) on the product body before touching 
the product, and touch the grounding metal bracket by hand to release the static electricity. 

 

It  is  suggested  to  wear  anti-static  suit  to  prevent  damage  to  the  equipment  caused  by  static 
electricity. 

 

When installing or maintaining the product, please wear anti-static wrist band or anti-static gloves. 
Make sure that the wristband is tightly attached to the skin and is reliably grounded. 

 

It is forbidden to touch exposed circuit boards with bare hands. Static electricity generated by 
human body may damage electrostatic sensitive components on circuit boards. 

 

When touching electrostatic sensitive components or devices, proper grounding measures must 
be taken. 

 

Put electrostatic sensitive components into anti-static bags for protection. 

 

It is suggested to place humidifier in dry environment to maintain suitable humidity and reduce 
static electricity generation. 

Maintenance 

 

If the product is not working properly, contact the store or the nearest service center. Do not 
disassemble or modify the device in any way. (The company does not bear any liability for any 
problem arising from unauthorized modification or maintenance). 

 

Please  properly  preserve  all  the  original  packaging  materials  of  the  product  so  that  when 
problems  arise, the  product  can be  packed  with  packaging  materials and  sent to the  agent  or 

Summary of Contents for SC3000 Series

Page 1: ...SC3000 Series Vision Sensor Quick Start Guide ...

Page 2: ...IAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY OR OTHERWISE IN CONNECTION WITH THE USE OF THE PRODUCT EVEN IF HIKROBOT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR...

Page 3: ...s equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experie...

Page 4: ...t avoided could result in equipment damage data loss performance degradation or unexpected results Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Available Model This manual is applicable to the SC3000 Series Vision Sensor Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid dange...

Page 5: ...to avoid heat accumulation Do not contact the radiator directly to avoid scald Electrostatic Protection Remove all conductive objects such as jewelry watch etc on the product body before touching the product and touch the grounding metal bracket by hand to release the static electricity It is suggested to wear anti static suit to prevent damage to the equipment caused by static electricity When in...

Page 6: ...for protection Installation Please do not install the product on vibrating surface or places that are vulnerable to impact Personnel Requirement Quality requirements for installation and maintenance personnel qualification certificate or working experience in weak current system installation and maintenance and relevant working experience and qualifications Besides the personnel must possess the f...

Page 7: ...off Firewall 8 5 3 Set PC Network 8 5 4 Set Device Network 9 5 5 Login 10 Chapter 6 Client Layout and Operation Flow 12 6 1 Main Window Introduction 12 6 2 Operation Flow 13 Chapter 7 I O and Serial Port Introduction 14 7 1 I O Electrical Feature 14 7 1 1 Input Signal 14 7 1 2 Output Signal 15 7 2 I O Wiring 18 7 2 1 Input Wiring 18 7 2 2 Output Wiring 20 7 3 RS 232 Serial Port 20 7 3 1 Introducti...

Page 8: ...s Vision Sensor Quick Start Guide vii 8 2 Why the image is not smooth in live view 22 8 3 Why the image is very dark 22 8 4 Why there is no image in live view 22 8 5 What can I do if I forget the login password 23 ...

Page 9: ... applicable to consumer electronics food and medical industry automobile etc 1 2 Key Feature Adopts embedded hardware platform for high speed image processing Adopts built in positioning and measurement algorithms to detect object s existence position dimension etc Multiple IO interfaces for input and output signals Multiple indicators for displaying device status Adopts light source to ensure uni...

Page 10: ...cation for detailed dimension information Figure 2 1 Appearance Table 2 1 Appearance Description No Name Description 1 17 Pin Interface It provides power input output Ethernet and serial port signal The interface is designed with screw threads to tighten connection between the device and cable and thus avoiding influence caused by vibration ...

Page 11: ... lamps providing light source Note The default color of LED lamps is white Red blue near infrared is optional 5 Screw It refers to the screw between device body and lens cap 6 Screw Hole It is used to fix the device to the installation position You should use M4 screw 7 PWR Indicator It is the power indicator The indicator is green when the device operates normally Otherwise it is red 8 STS Indica...

Page 12: ...rple white 4 RS232TX RS232 serial port output Green 5 RS232RX RS232 serial port input Green white 6 MDI0 Fast Ethernet signal MDI0 Yellow 7 MDI1 Fast Ethernet signal MDI1 Orange white 8 DO_0 Line 5 signal line Opto isolated output Blue white 9 I O_0 Line 2 signal line Can be configured as input or output Blue 10 DO_1 Line 6 signal line Opto isolated output Brown white 11 GND Signal ground Direct c...

Page 13: ...to isolated input Gray 17 DI_1 Line 1 signal line Opto isolated input White Note You should refer to the table above and the label attached to the power and I O cable to wire the device It is recommended to use the supplied 17 pin cable The 6th 7th 14th and 15th pin have been made as RJ45 connector The lines of other pins should be wired according to the actual demands ...

Page 14: ...also use polarization or infrared filter lens cap that needs to be purchased separately 5 Light Source 1 It refers to the supplied white light source You can also use red blue near infrared light source that needs to be purchased separately 6 M4 Screw 4 It refers to the supplied M4 screw that is used to fix the device to the installation position 7 Mounting Panel 1 It is used to install the device...

Page 15: ... remote operations Note Check the Windows version The client software is compatible with 32 64 bit Windows XP 7 10 You can get the client software installation package from https en hikrobotics com The graphic user interface may differ by different versions of client software you use Steps 1 Double click the installation package to install the client software 2 Select the language 3 Read and check...

Page 16: ...ol Panel System and Security Windows Defender Firewall 2 Click Turn Windows Defender Firewall on or off on the left 3 Select Turn off Windows Defender Firewall not recommended Figure 5 2 Windows Defender Firewall 4 Click OK 5 3 Set PC Network To ensure stable image transmission and normal communication between the PC and the device via client software you need to set the PC network before using th...

Page 17: ...pter 2 Select corresponding network interface card and click Link Speed 3 Set Speed and Duplex as Auto Negotiation or 100 Mbps 5 4 Set Device Network You can set and operate the device in the client software only when the device is in the same network segment with the PC where the client software is installed Steps 1 Double click the client software to run it 2 Click in the device list to find the...

Page 18: ...u installed the client software before connecting the device to it The default login password is Abc1234 and it is highly recommended to change the password for the first time use Follow the guidance to find the password if you forget it Refer to the user manual of the SCMVS client software for detailed operation Steps 1 Click the device in the device list 2 Enter password 3 Click to log in ...

Page 19: ...SC3000 Series Vision Sensor Quick Start Guide 11 Figure 5 5 Login Interface 4 Optional Check Remember me to remember the password if necessary ...

Page 20: ...fter logging in If there is no project the client software will create and run a new project Table 6 1 Main Window Description No Name Description 1 Menu Bar The menu bar includes project I O settings communication settings camera settings and operation management 2 Project Status Display Area This area displays operation results of current projects in real time You can run stop or edit projects h...

Page 21: ... information here 6 2 Operation Flow Note Refer to the user manual of the SCMVS client software for detailed parameter settings and operations Click More on the upper right corner of the client software and click User Manual to open it You can follow the overall operation flow below to operate the device via the client software Log into Client Software Create Edit Project Parameters Settings Base ...

Page 22: ...gnals Note The two input signals and three bi directional I O signals can also be used as signal sources to switch the device s projects Refer to the user manual of the SCMVS client software for details 7 1 I O Electrical Feature 7 1 1 Input Signal The device s Line 0 1 are input signals and Line 2 3 4 are bi directional I O signals that can be set as input The internal circuit of input signal is ...

Page 23: ... 24 VDC 7 56 VDC to 12 VDC VCC 12 VDC Input Falling Delay TDF 1 3 μs to 3 5 μs Input Rising Delay TDR 1 3 μs to 3 5 μs Note VCC is the device s input voltage The breakdown voltage is 36 VDC and keep voltage stable 7 1 2 Output Signal The device s Line 5 6 7 are output signals and Line 2 3 4 are bi directional I O signals that can be set as output You can go to I O settings of the client software t...

Page 24: ... Quick Start Guide 16 Figure 7 3 Set I O Output Type Note The maximum output current of output signal is 200 mA If the output signal is PNP type its internal circuit is shown below Figure 7 4 Internal Circuit of PNP Output Signal ...

Page 25: ...resistance is 12 VDC and 1 KΩ respectively the electrical feature of output signal is as follows Note With different external voltage and resistance the corresponding current and output logic level low may have small change Table 7 2 Output Electrical Feature Parameter Name Parameter Symbol Value Output Logic Level Low VL 212 mV Output Logic Level High VH 11 8 VDC Output Falling Delay TDF 0 4 μs O...

Page 26: ...ly and the actual one you got should prevail 7 2 1 Input Wiring Two types of input wiring are available and you can wire the device according to actual demands Note Input signal wiring may differ by external device types It is recommended to use the first type of input wiring because this type is applicable to all I O input signals including Line 0 1 2 3 4 The second type of input wiring is only a...

Page 27: ...cts to NPN Device Switch It is recommended to use 1 KΩ pull down resistor Figure 7 9 Input Signal Connects to a Switch Second Type of Input Wiring PNP Device If you do not have available external resistors you can wire the device as shown below Input Signal Device Power PWR Device Power Ground PNP Device PNP Device Power PNP Device Power Ground Signal Line VCC GND IN_COM Figure 7 10 Configurable I...

Page 28: ...e If the external device is PNP you should set the device s output signal polarity as NPN If the external device is NPN you should set the device s output signal polarity as PNP Output Signal Line Device Power PWR Device Power Ground External Device External Device Power External Device Power Ground Signal Line VCC GND Figure 7 12 Output Wiring Note When the device s output signal is set as NPN th...

Page 29: ...ale Connector Figure 7 14 25 Pin Male Connector Table 7 3 RS 232 Pin Description Serial Port Type Pin No Name Function 9 Pin Interface 2 RX Receive data 3 TX Send data 5 GND Signal ground 25 Pin Interface 2 TX Send data 3 RX Receive data 7 GND Signal ground 7 3 2 Wiring You can refer to the serial port wiring below to connect the device with an external device Device Power PWR Device Power Ground ...

Page 30: ...he same network segment 8 2 Why the image is not smooth in live view Reason The network transmission speed is not up to 100 Mbps Solution Check if the network transmission speed is up to 100 Mbps 8 3 Why the image is very dark Reason The brightness of light source is not enough Exposure and gain values are too small Solution Increase the brightness of light source or use brighter lamps Increase ex...

Page 31: ...heck if the network transmission speed is up to 100 Mbps 8 5 What can I do if I forget the login password Solution Click Forgot Password in the login interface to view the device serial No and mail it to the technical support personnel or call them to get the corresponding resetting file After that import the resetting file and reset the password as the default one ...

Page 32: ...UD24212B ...