Camera Link Line Scan Camera
·
User Manual
26
4.
Click Frequency Converter Control, and select specific line, Encoder Module Out or
CC1/CC2/CC3/CC4 as Input Source according to actual demands.
N/A means that input source is not used.
5.
Set Rising Edge or Falling Edge as Signal Alignment according to actual demands.
6.
Set PreDivisder, Multiplier and PostDivider.
Figure 7-10
Set Frequency Converter Control
7.6.5 View Trigger Line Rate
Parameters of trigger line rate and resulting trigger line rate may differ by camera models.
Trigger Line Rate: It refers to the external trigger raw line rate after filtering, and it only
involves external trigger signals.
Resulting Trigger Line Rate: It refers to the external trigger frequency cameras received after
the external trigger raw line rate is calculated via frequency converter control. It only involves
external trigger signals.
You need to select external trigger sources as Input Source to display specific values in Trigger Line
Rate and Resulting Trigger Line Rate. If N/A is selected as Input Source, these two parameter
values will be 0.