10
English
●
Lamp indication
The indications of the pilot lamp will be as shown in
Table 1
, according to the condition of the charger or the
rechargeable battery.
Table 1
Indications of the pilot lamp
Charge
status lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
While charging Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o
ff
for 0.1 seconds)
Malfunction in the battery
or the charger
Overheat
lamp (green)
Overheat
standby
Lights
Lights continuously
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
●
Regarding the temperatures and charging time of the rechargeable battery
The temperatures and charging time will become as shown in
Table 2
.
Table 2
Charger
Battery
UC18YRL
Charging voltage
V
7.2 – 18
Type of battery
Ni-Cd
Ni-MH
Li-ion
Temperatures at which the battery can be
recharged
-5
o
C – 55
o
C
-5
o
C – 50
o
C
0
o
C – 50
o
C
Charging time for battery capacity, approx.
(At 20
o
C)
1.2 – 1.4 Ah
1.5 Ah
2.0 Ah
2.4 Ah
2.6 Ah
3.0 Ah
3.3 Ah
min.
min.
min.
min.
min.
min.
min.
20
20
30
35
–
–
–
–
20
30
–
40
45
50
–
20
30
–
–
45
–
Number of battery cells
7.2 V
9.6 V
12 V
pcs.
pcs.
pcs.
6
8
10
–
8
10
–
–
–
14.4 V
pcs.
12
12
1.5/2.0 Ah : 4
3.0 Ah : 8
18 V
pcs.
15
15
1.5/2.0 Ah : 5
3.0 Ah : 10
CAUTION
○
If the battery is charged while it is heated because it
has been left for a long time in a location subject to
direct sunlight or because the battery has just been
used, the overheat lamp of the charger lights up
green. In such a case,
fi
rst let the battery cool, then
start charging.
○
When the charge status lamp
fl
ickers in red (at
0.2-seconds intervals), check for and take out any
foreign objects in the charger’s battery installation
hole. If there are no foreign objects, it is probable that
the battery or charger is malfunctioning. Take it to your
authorized Service Center.
NOTE
The recharging time may vary according to the
ambient temperature and power source voltage.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger
fi
rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
000Book̲UC18YRL.indb 10
000Book̲UC18YRL.indb 10
2019/07/26 11:00:52
2019/07/26 11:00:52