EVC - USER MANUAL 

3

 

Manual mode activated. The connected drive mechanism was 

operated manually (with arrow keys) or 

 key was pressed. Thus, 

the automatic functions are deactivated, there is no control in terms 

of temperature. The safety functions rain alarm and wind alarm are 

still activated. The control is in manual mode until you change to 

automatic mode with 

 key. 

 

 

Rain alarm. The window is closed, manual operation is blocked. The 

rain protection function may be turned on and off in the automatic 

settings. 

 

Wind alarm. The window is closed, manual operation is blocked. The 

wind protection function may be set up or turned off in the automatic 

settings. 

Manual control as well as the presetting of the automatic functions and the basic 

setting of the connected shading is accomplished with the keys of the operating 

unit. 

 

   

 

 

   Up   

  Stop  

 Down 

 

The connected window may be manually operated with the keys 

 and  . The 

arrow keys are provided with a time automatic. By short pressing (less than 1 

second), the window may be exactly positioned. If the key is pressed more than 1 

second, the drive mechanism moves automatically to the final position. If you 

press  , the drive mechanism stops. 

In case of rain or wind alarm, the manual operation is blocked. 

 

OVERVIEW

Summary of Contents for EVC

Page 1: ...INSTALLATION USER MANUAL EVC RAIN TEMPERATURE CONTROL UNIT ...

Page 2: ...temperature lower line as well as the function mode automatic or manual the battery load and the current alarm messages for rain or wind The meteorological data are updated once per minute and in case of a keystroke Outdoor temperature Indoor temperature Battery symbol indicates the charge status of the battery full half full empty Automatic mode activated ...

Page 3: ...he window is closed manual operation is blocked The wind protection function may be set up or turned off in the automatic settings Manual control as well as the presetting of the automatic functions and the basic setting of the connected shading is accomplished with the keys of the operating unit Up Stop Down The connected window may be manually operated with the keys and The arrow keys are provid...

Page 4: ...of temperature With key the control is reset to automatic display If the next automatic command is an opening command then the control closes the window at first 4 minute reference movement After that the opening position is initiated E D O C T U P N I E G A T L O V T U P T U O E G A T L O V T N E R R U C T U P T U O S S A L C N O I T C E T O R P 96x77x118mm S N O I S N E M I D C A V 0 3 2 C A V 0...

Page 5: ...lified professional Do not use cable thicker than 1 5mm and multi strand if possible for flexibility Wire all other inputs before connecting mains power PROG 230V AC MAINS POWER L1 N PE LIVE NEUT EARTH PE N OPEN CLOSE LIVE 2 OPEN LIVE 1 CLOSE NEUTRAL EARTH M 230V ACTUATOR EVC WEATHER STATION WIRING ...

Page 6: ...lash twice to confirm pairing 3 4 Insert 2 x AA batteries inside the control unit 1 Press or to select the channel you want to pair L1 L8 2 3 Press the centre of the button on the hand held transmitter until an L for Learn and a number channel are displayed Turn on the power to the Weather Station then press the LEARN button inside The LED on the Weather Station will flash twice to confirm pairing...

Page 7: ...external temperature Then press to confirm your selection To turn off the External Temperature function adjust the temperature below 20 OFF then press 1 2 Windows will stay closed if external temperature is below the parameter set Wind Sensor Use the buttons to select the desired wind value Then press to confirm your selection To turn off the Wind Sensor function adjust the wind value below 0 OFF ...

Page 8: ......

Reviews: