Tables and pictures show the technical data and dimensions of the vacuum cleaner. 

This  warranty  covers  only  manufacturing  defects.  Pantheon  does  not  assume 

damage  in  the  transport,  unpacking  or  operation.  The  manufacturer  is  not 

responsible  for  any  damage or defects caused by improper  use, corrosion or use of 
specifications  beyond  the  noted  specifications.  The  manufacturer  shall  not  be 

responsible  for  any  indirect  damage  or  expense  under  any  circumstances

For 

complete  information  on  the  manufacturer's  warranty  period

please  refer  to  the 

current warranty terms of Pantheon. Local retailer may has special warranty terms

If 

you have any uncertainty about the warranty terms, please contact with your retailer

IVC-45L 

Power  (KW) 

5.5 

Rated  Voltage  (V) 

380V/220V  {3P) 

Rated Current(A) 

13.3/25 

Max.Suction  (Kpa) 

30 

Max. Airflow(m

3

/h) 

600 

Recommended minimum 

cable size(m

2

/h) 

3*4+1*2.5 

Overall  Filter  Area(m2) 

2.8 

Filter  Degree 

HEPA13 

Weight(kg) 

223.5 

Size,  (LxWxH)  (mm) 

1250*711*1930 

Lifting Size (mm) 

1250*711*1630 

7. Technical Data

8. Warranty

Summary of Contents for IVC-45L

Page 1: ...aker Avenue Englewood Colorado 80110 Customer Support Sales 1 720 504 5800 Email sales pantheonsurfaceprep com California Branch Address 5556 Corporate Avenue Cypress California 90630 Customer Support Sales 1 714 527 6700 Email info pantheonsurfaceprep com ...

Page 2: ...leaning ________________________________________________________ 16 1 8 Handling and storage ______________________________________________ 02 2 1 Overview ________________________________________________________ 03 2 2 Operational safety guidance 03 2 3 Electrical Safety guidance __________________________________________ 04 5 3 1 Clean cyclone separator 16 5 3 2 Clean the filters 16 5 4 Overload...

Page 3: ...ure to follow the prescribed steps 1 7 Machine nameplate 1 4Transportation Always ensure that the vacuum cleaner has emptied dust and other particles before transporting lifting or before lifting Make sure the vacuum cleaner is securely fastened and remember to press the brake pads of wheels to prevent the device from moving during transportation Ensure that the safety belt or other device used fo...

Page 4: ...he working voltage HZ is same with input Voltage and HZ no lack of phase of input power lf the machine do not work normally and it results in the input power and working power is not the same then manufacturers warranty is unavailable 6 The machine should be connected to appropriate electrical outlet Only use power cables that can withstand high current 7 Connecting with a grinder to achieved dust...

Page 5: ...plays the current vacuum pressure in filter bucket When the value of pressure gauge not considering the symbol becomes larger and larger it means that there is dust clogging in the suction hose or excessive dust accumulation on the filter Then shake the vacuum hose to clear it 6 Timer shows the cumulative running time of the device 1 Filter barrelassembly 2 Rack components 3 Control panel 4 Index ...

Page 6: ...k it 4 1 Overview The following sections describe the vacuum cleaner at different locations during operation the main operation and how to install the longopac dust bag Note 1 Vacuum cleaners can only be used or repaired by personnel who have received the necessary theoretical and practical training and have carefully read the user manual 2 Wear protective equipment such as protective gloves prote...

Page 7: ...acuum cleaner is adjusted to the position of transportation and there is a risk of crushing injury 4 Dust inhalation is harmful Please bring a professional mask during operation to ensure physical safety 4 3 Connection of hose and vacuum cleaner The IVC 45L is equipped with an 80mm connector which can quickly and safely connect the grinder and the vacuum cleaner 4 4 Start and stop the vacuum clean...

Page 8: ......

Page 9: ...sed of a dust bag hanging barrel and dust bag Install the dust bag on dust bag hanging barrel and then install the barrel under the cyclone separation barrel and the filter barrel respectively Before the vacuum cleaner is ready for work pull the dust bag from the dust bag hanging bucket and tie it with a cable tie to prepare for dust collection After the vacuum cleaner has been running for a perio...

Page 10: ...lowest transport position disassemble locking buckle and remove the filter barrel cover Take out the filter to see if it is covered with dust ifitis putitina plastic bag for vibration cleaning Check the internal hose check whether the internal hose is intact and replace the hose if necessary Check draught fan remove the fan cover check whether the fan is blocked by dust and clean it if necessary W...

Page 11: ...Control circuit damage Contact a licensed electrician or Pantheon Service center The vacuum cleaner stops after starting Some objects obstruct airflow Clean hoses filters etc Relay overload protection For the operation steps see 5 5 Overloading Protection The machine uttered a low buzz when turn on and turn off Phase lost input currently only two phase inputs Turn off the machine to avoid burning ...

Page 12: ...direct damage or expense under any circumstances For complete information on the manufacturer s warranty period please refer to the current warranty terms of Pantheon Local retailer may has special warranty terms If you have any uncertainty about the warranty terms please contact with your retailer IVC 45L Power KW 5 5 Rated Voltage V 380V 220V 3P Rated Current A 13 3 25 Max Suction Kpa 30 Max Air...