High-Flying
HF-LPT100 Low Power WiFi Module User Manual
Shanghai High-Flying Electronics Technology Co., Ltd(www.hi-flying.com)
- 56 -
Parameters:
ret:
normal: normal mode (100ms interval)
mode:
normal: normal mode (100ms interval)
standby: WiFi shut down mode.
(Reserved)
4.2.2.61.
AT+NTPRF
Function: Set /Query time calibration interval
Format:
Query Operation
AT+NTPRF<CR>
+ok=<num><CR><LF><CR><LF>
Set Operation
AT+NTPRF=<num><CR>
+ok<CR><LF><CR><LF>
Parameters:
num
:
time calibration inverval
,
range:0~720, default:30 minutes, 10 minutes for
each step, set 0 means no time calibration automatically.
4.2.2.62.
AT+NTPEN
Function: Enable/Disable time calibration function. Setting is valid after reset.
Format:
Query Operation
AT+NTPEN<CR>
+ok=<status><CR><LF><CR><LF>
Set Operation
AT+NTPEN=<status><CR>
+ok<CR><LF><CR><LF>
Parameters:
status
:
status of time calibration
on
:
Enable time calibration
off
:
Disable time calibration
4.2.2.63.
AT+NTPTM
Function: Query network time
Format:
Query Operation
AT+NTPTM<CR>
+ok=<time><CR><LF><CR><LF>
Parameters:
time
:
networ time, for example: 2013-10-9 16:10:42 Wed
,
if it shows Not
Available means that the time calibration function is not enabled or the module
doesn’t connect to the internet.