Overview of Characteristic 

 

Support 802.11b/g Wireless Standard, STA Mode 

 

Support Bluetooth 2.1+EDR Standard 

 

Support Bluetooth SmartLink 

 

Cost Effective Solution With High-Flying MCU 

 

Support UART/GPIO Data Communication Interface 

 

Support Wireless/Remote Firmware Upgrade 

 

Provide SDK for Application develop 

 

Support Internal/External Antenna Option 

 

Smallest Size

23.1mm x 32.8mm x (3.45

±

0.3)mm 

 

Wide Input Voltage

3.3V~ 4.2V 

 

FCC/CE Certificated 

 

High-Flying

Summary of Contents for HF-LPC100

Page 1: ... Wireless Standard STA Mode Support Bluetooth 2 1 EDR Standard Support Bluetooth SmartLink Cost Effective Solution With High Flying MCU Support UART GPIO Data Communication Interface Support Wireless Remote Firmware Upgrade Provide SDK for Application develop Support Internal External Antenna Option Smallest Size 23 1mm x 32 8mm x 3 45 0 3 mm Wide Input Voltage 3 3V 4 2V FCC CE Certificated H i g ...

Page 2: ...on 16 1 6 Typical Application 17 1 6 1 Hardware Typical Application 17 1 7 Bluetooth Sonic Configuration 18 2 FUNCTION DESCRIPTION 19 2 1 Wireless Networking 19 2 2 Work mode Transparent Transmission Mode 19 2 3 UART Frame Scheme 20 2 3 1 UART Free frame 20 2 3 2 UART Auto Frame 20 2 4 Bluetooth Function 21 2 5 Firmware Upgrade 21 2 6 GPIO PWM Function TBD 23 2 7 Double SOCKET Communication Functi...

Page 3: ...22 AT PING 34 3 2 2 23 AT NETP 35 3 2 2 24 AT MAXSK 35 3 2 2 25 AT TCPLK 36 3 2 2 26 AT TCPTO 36 3 2 2 27 AT TCPDIS 36 3 2 2 28 AT SOCKB 37 3 2 2 29 AT TCPDISB 37 3 2 2 30 AT TCPTOB 38 3 2 2 31 AT TCPLKB 38 3 2 2 32 AT UDPLCPT 38 3 2 2 33 AT SNDB 38 3 2 2 34 AT RCVB 39 3 2 2 35 AT WSSSID 39 3 2 2 36 AT WSKEY 39 3 2 2 37 AT WANN 40 3 2 2 38 AT WSMAC 40 3 2 2 39 AT BTMAC 40 3 2 2 40 AT WSLK 41 3 2 2...

Page 4: ...ice Handling Instruction Module IC SMT Preparation 48 4 3 Shipping Information 49 APEENDIX A HARD REFERENCE DESIGN 50 APPENDIX B CONTROL GPIO PWM FUNCTION WITH NETWORK COMMAND TBD 51 B 1 Network Command 51 B 2 Hexadecimal Network Command 54 APPENDIX C HTTP PROTOCOL TRANSFER 57 C 1 HTTP AT Command 57 C 1 1 AT HTTPURL 57 C 1 2 AT HTTPTP 57 C 1 3 AT HTTPPH 57 C 1 4 AT HTTPCN 58 C 1 5 AT HTTPUA 58 C 1...

Page 5: ...F LPC100module placement region 14 Figure 6 HF LPC100 Evaluation Kit TBD 15 Figure 7 HF LPC100 order information 16 Figure 8 HF LPC100 hardware typical application 17 Figure 9 Basic HF LPC100 wireless networking structure 19 Figure 10 Double Socket setting view 24 Figure 11 HF LPC100 Default UART parameter 25 Figure 12 Switch to configuration mode 25 Figure 13 AT H instruction for help 26 Figure 1...

Page 6: ... HF LPC100 Pins Definition 10 Table 3 Electrical Characteristic 12 Table 4 Power Supply Power Consumption 12 Table 5 HF LPC100 External Antenna Parameter 14 Table 6 HF LPC100 Evaluation kit interface description 15 Table 8 HF LPC100 GPIO PWM Pin mapping table 23 Table 10 Error Code Description 27 Table 11 AT Instruction Set List 27 Table 12 reflow soldering parameter 48 H i g h F l y i n g ...

Page 7: ...HF LPC100 Wi Fi Bluetooth Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 7 HISTORY V 1 0 12 05 2014 First version H i g h F l y i n g ...

Page 8: ...he home automation smart grid handheld device personal medical application and industrial control that have lower data rates and transmit or receive data on an infrequent basis The HF LPC100 integrates all Wi Fi functionality into a low profile 23 1x32 8x 3 45 0 3 mm SMT module package that can be easily mounted on main PCB with application specific circuits Also module provides built in antenna e...

Page 9: ...rface UART SPI PWM GPIO Operating Voltage 3 3 4 2V Operating Current Peak Continuous TX 220mA Average 30mA Peak 220mA Operating Temp 25 85 Storage Temp 45 125 Dimensions and Size 23 1mm 32 8mm 3 45 0 3 mm Software Parameters Network Type STA BT2 1 Security Mechanisms WEP WPA PSK WPA2 PSK Encryption WEP64 WEP128 TKIP AES Update Firmware Local Wireless Remote Customization Web Page Upgrade Support S...

Page 10: ... Hardware Introduction Figure 1 HF LPC100 View 1 5 1 Pin Definition Figure 2 HF LPC100 Pins map Table 2 HF LPC100 Pins Definition Pin Describtion Net Name Signal Type Comments 1 17 32 48 Ground GND Power 2 Debug Pin SWCLK I PD Debug functional pin No connect if not use 3 NC 4 NC 5 Debug Pin SWD I O PU H i g h F l y i n g ...

Page 11: ... C No connect 25 USB1 1 D USB_DP I O GPIO25 No connect if not use 26 USB1 1 D USB_DM I O GPIO26 No connect if not use 27 GPIO GPIO27 I O GPIO27 No connect if not use 28 N C No connect 29 N C No connect 30 GPIO AD GPIO30 I O GPIO30 No connect if not use 31 3 3V Power DVDD Power 33 N C No connect 34 3 3 Power DVDD Power 35 WPS Function WPS I O GPIO35 No connect if not use 36 N C No connect 37 N C No...

Page 12: ...ition Min Typ Max Unit Storage temperature range 45 125 C Maximum soldering temperature IPC JEDEC J STD 020 260 C Supply voltage 0 3 8 V Voltage on any I O pin 0 3 3 V ESD Human Body Model HBM TAMB 25 C 2 KV ESD Charged Device Model CDM TAMB 25 C 1 KV Table 4 Power Supply Power Consumption Parameter Condition Min Typ Max Unit Operating Supply voltage 2 8 3 3 3 8 V Supply current peak Continuous Tx...

Page 13: ...ying Electronics Technology Co Ltd www hi flying com 13 1 5 3 Mechanical Size HF LPC100 physical size unit mm as below Figure 3 HF LPC100 Mechanical Dimension HF LPC100 module PCB symbol size unit mm as below Figure 4 HF LPC100 PCB symbol size H i g h F l y i n g ...

Page 14: ...nclosure All cover include plastic shall away from antenna at least 10mm Meanwhile please contact High Flying technique support to assist regarding module placement and Layout design Figure 5 HF LPC100module placement region 1 5 5 External Antenna HF LPC100 module supports internal antenna and external antenna I PEX option for user dedicated application If user select external antenna HF LPC100 mo...

Page 15: ...6 HF LPC100 Evaluation Kit TBD Notes User need download USB to UART port driver from High Flying web or contact with technical support people for more detail The external interface description for evaluation kit see Table 6 Table 6 HF LPC100 Evaluation kit interface description Function Name description External interface COM1 data command RS 232 interface 1 JTAG JTAG data debug interface not avai...

Page 16: ...t up ok off module boot up failed twinkle remote upgrading twinkle frequency and download speed is in direct proportion Button nReset Reset button nReload Press the button over 3 seconds to restore factory setting 1 5 7 Order Information Based on customer requirement HF LPC100 can support difference variants and physical type detail as below Figure 7 HF LPC100 order information H i g h F l y i n g...

Page 17: ... LED indicate status when the module in wireless upgrade mode When module connects to AP AP associated this pin will output 0 This signal used to judge if module already at WiFi connection status Thers is pull up resister internal and no external pull up required If nLink function not required can leave this pin open nReady Module boot up ready signal Output Logics 0 effective The module will outp...

Page 18: ...e of audio transmit Bluetooth enable module receive audio information sent from smart terminal The APP on smart terminal compile the router s password and ID to audio signal and play it through Bluetooth Then the Wi Fi module with Bluetooth will analysis the audio signal and realize the Wi Fi connection Nowadays Bluetooth is the standard deployment on smart terminal Since the good support to audio...

Page 19: ...onnect to the default wireless network and server As in this mode the module s serial port always work in the transparent transmission mode so users only need to think of it as a virtual serial cable and send and receive data as using a simple serial In other words the serial cable of users original serial devices is directly replaced with the module user devices can be easy for wireless data tran...

Page 20: ... be around 40 50 ms if data is small If the interval is 10ms and customers MCU can not send next byte within 1oms then the UART data may be divided as fragment Through AT command AT UARTTE fast normal to set interval time fast means 10ms normal means 50ms 2 3 2 UART Auto Frame For data frame on UART Module can be more effective by open UART auto frame function HF LPC100 support UART auto frame fun...

Page 21: ...firmware and application HF LPC100 module also support upgrade from remote HTTP server keep module connects to AP router before execute remote HTTP upgrade Remote upgrade have two methods Direct Download and Upgrade Configure File Based Upgrade Configure file based upgrade AT UPURL command to set the remote directory which the configuration file located For example AT UPURL http www hi flying com ...

Page 22: ...e User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 22 Notes please contact with high flying technical people before upgrade firmware or maybe damage the module and can t work again H i g h F l y i n g ...

Page 23: ...ponse GPIO OK or GPIO NOK PWM n GET Read PWMn Channel set Response ok frequency duty or PWM NOK PWM n SET Save PWMn Channel set Response PWM OK or PWM NOK Notes Please refer to Appendix B for details 2 7 Double SOCKET Communication Function HF LPC100 WI FI module support double socket communication the Socket B function is disabled by default After the module boot up send command AT SOCKB to set t...

Page 24: ...HF LPC100 Wi Fi Bluetooth Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 24 Figure 10 Double Socket setting view H i g h F l y i n g ...

Page 25: ...0 User Name admin Password admin Figure 11 HF LPC100 Default UART parameter In configuration mode user can configure module by AT Instruction via UART port Notes for AT command debug tool we recommend use SecureCRT or High Flying APP User can download from our website all below introduction applied our tools 3 1 1 Switch to Configuration Mode Two steps to finish switching from transparent transmis...

Page 26: ...user can set check reset module or back to transparent transmission mode by AT Instruction via UART port Details instruction refer to next chapter 3 2 AT Instruction Set Overview User can input AT Instruction through hyper terminal or other serial debug terminal also can program the AT Instruction to script User can also input AT H to list all AT Instruction and description to start Figure 13 AT H...

Page 27: ... AT Instruction AT CMD character will display capital letter automatic and other parts will not change as you input Response Message RSP op para 1 para 2 para 3 para 4 CR LF CR LF Prefix of response message RSP Response string ok Success ERR Failure op para n Parameters if query command or Error code when error happened CR ASCII 0x0d LF ASCIII 0x0a Error Code Table 10 Error Code Description Error ...

Page 28: ...Default Parameters UART instruction set UART Set Query serial port parameters UARTF Open Close UART auto frame function UARTFT Set Query UART auto frame trigger time UARTFL Set Query UART auto frame trigger length UARTTE Set Query UART free frame trigger time between two bytes Command Mode Set SEND Send Data at Command Mode RECV Receive Data at Command Mode Network Instruction Set PING Network Pin...

Page 29: ...LOGSW Open Close remote upgrade log LOGPORT Set Query UDP port of remote upgrade log UPST Start remote Application upgrade Power Management Instruction Set MSLP Set module to low power mode Network Time Set NTPRF Set Query time calibration interval NTPEN Enable Disable time calibration function NTPTM Query time NTPSER Set Query NTP server IP Others Instruction Set WRMID Set module ID RLDEN Set Que...

Page 30: ... command module switch from configuration mode to transparent transmission mode 3 2 2 3 AT TMODE Function Set Query module data transfer mode Setting is valid after reset Format Query AT TMODE CR ok tmode CR LF CR LF set option AT TMODE tmode CR ok CR LF CR LF parameter tmode data transfer mode includes throughput throughput mode cmd command mode pwm PWM GPIO mode 3 2 2 4 AT MID function query mod...

Page 31: ...AT RELD Function module restore to factory default setting Format AT RELD CR ok rebooting CR LF CR LF When operate this command module will restore to factory default setting and reboot 3 2 2 8 AT FCLR Function erase factory setting Format Query operation AT FCLR CR ok CR LF CR LF 3 2 2 9 AT Z Function re start module Format AT Z CR 3 2 2 10 AT H Function Help Format AT H CR ok command help CR LF ...

Page 32: ...ery operation AT CFGFR CR ok config CR LF CR LF Parameter config the first two bytes means the length of read configure parameter 3 2 2 14 AT CFGTF Function copy user configure parameter to factory default configure parameter Format Query AT CFGTF CR ok status CR LF CR LF Parameter status feedback operation status 3 2 2 15 AT UART Function set query serial parameter setting is valid after reset Fo...

Page 33: ...RTF CR ok para CR LF CR LF Set operation AT UARTF para CR ok CR LF CR LF Parameter para disable close auto frame function enable open auto frame function 3 2 2 17 AT UARTFT Function set query UART auto frame trigger time Format Query operation AT UARTFT CR ok time CR LF CR LF Set operation AT UARTFT time CR ok CR LF CR LF Parameter time auto frame trigger time unit ms range 100 10000 3 2 2 18 AT U...

Page 34: ...50ms 3 2 2 20 AT SEND Function send data to SOCKA at command mode Format AT SEND data_lenth CR ok CR LF CR LF Parameter data_lenth Length of send data Range 0 1000 Byte The UART port will wait 3 seconds for input after this command is succeed and feedback The data received from UART port is sent to SOCKA If the interval of two bytes is more than 10ms the data will be sent instantly 3 2 2 21 AT REC...

Page 35: ...ype include TCP UDP CS network mode SERVER CLIENT Port protocol port ID decimal digit and less than 65535 IP server s IP address or domain name when module set as client If set as UDP SERVER the module will save the IP address and port of the latest UDP packet received and send data to the saved IP address and port When module under initialization status it will send data to this IP address and po...

Page 36: ...CPTO CR ok time CR LF CR LF Set operation AT TCPTO time CR ok CR LF CR LF Parameter Time TCP timeout time 600 600s 0 0 means no timeout setting Default 300s Module begin to count time when TCP channel don t receive any data clear time counter when TCP channel receive any data If the time counter reaches the TCPTO the TCP channel will be break If the module work in TCP Client it will connect the TC...

Page 37: ...es TCP only means TCP Client UDP UDP client UDPS UDP server Port protocol port decimal digital less than 65535 IP target IP address support domain name If set as UDP SERVER the module will save the IP address and port of the latest UDP packet received and send data to the saved IP address and port When module under initialization status it will send data to this IP address and port set by the comm...

Page 38: ...o send TCPDISB command to reconnect 3 2 2 31 AT TCPLKB Function set query SOCKB connection status Format AT TCPLKB CR ok sta CR LF CR LF Parameter sta SOCKB connection status on TCP connected off TCP disconnect 3 2 2 32 AT UDPLCPT Function set query local port of Socket A Socket B when work as UDP communication Format Query operation AT UDPLCPT CR ok porta portb CR LF CR LF Set operation AT UDPLCP...

Page 39: ...ta_lenth data_content CR LF CR LF Parameter data_lenth length of received data range 0 1000 byte data_content content of received data If no data received in 3s feedback ok 0 3 2 2 35 AT WSSSID Function set query associated AP SSID parameter setting is valid after reset Format Query operation AT WSSSID CR ok ap s ssid CR LF CR LF Set operation AT WSSSID ap s ssid CR ok CR LF CR LF Parameter ap s s...

Page 40: ...t Query operation AT WANN CR ok mode address mask gateway CR LF CR LF Set operation AT WANN mode address mask gateway CR ok CR LF CR LF Parameter mode STA s IP network setting static static IP DHCP dynamic IP address STA IP address mask STA subnet mask gateway STA gateway address 3 2 2 38 AT WSMAC Function set query STA MAC parameter setting is valid after reset Format Query operation AT WSMAC CR ...

Page 41: ...T WSLK Function query STA wireless link status Format Query operation AT WSLK CR ok ret CR LF CR LF Parameter ret if no connect feedback Disconnected if connected feedback AP SSID AP s MAC 3 2 2 41 AT WSLQ Function query AP Wi Fi signal strength Format Query operation AT WSLQ CR ok ret CR LF CR LF Parameter ret if no connect feedback Disconnected if connected feedback Wi Fi signal strength 3 2 2 4...

Page 42: ...ok url CR LF CR LF Set operation AT UPURL url filename CR ok CR LF CR LF Parameter url the upgrade file located URL address Note there should be in the tail utmost support 100 bytes filename upgrade file name may choose not save If provide this file name here the module will start upgrade right away 3 2 2 45 AT UPFILE Function set query remote upgrade file name format query operation AT UPFILE CR ...

Page 43: ... LOGPORT CR ok port CR LF CR LF Set operation AT LOGPORT port CR ok CR LF CR LF Parameter port the remote upgrade USP port of log file 3 2 2 48 AT UPST Function start remote upgrade Format Query operation AT UPST CR ok log CR LF CR LF Parameter log feedback the status of remote upgrade Note After execute this command the HF LPC100 will automatic start upgrade base on the setting of UPURL UPFILE li...

Page 44: ... CR ok CR LF CR LF parameter num time calibration interval range 0 720 default 30 minutes 10 minutes for each step set 0 means no time calibration 3 2 2 51 AT NTPEN Function enable disable time calibration function Setting is valid after reset Format Query operation AT NTPEN CR ok status CR LF CR LF Set operation AT NTPEN status CR ok CR LF CR LF Parameter status status of time calibration on enab...

Page 45: ...dress CR ok CR LF CR LF Parameter ipaddress NTP network server IP address 61 164 36 105 default value 3 2 2 54 AT WRMID Function set module ID Format Set operation AT WRMID wrmid CR ok CR LF CR LF Parameter wrmid set module s ID within 20 characters 3 2 2 55 AT RLDEN Function set query nReload function Format Query operation AT RLDEN CR ok status CR LF CR LF Set operation AT RLDEN status CR ok CR ...

Page 46: ... itself in one minute Auto Enable Wi Fi auto detect function The module will reset itself when encounter any abnormal The default time interval is 10 minutes default mode 3 120 unit minute Set the time interval to reset itself when abnormal 3 2 2 58 AT TXPWR Function Set Query Wi Fi Transmit Power Real Transmit Power Default Transmit Power 16dBm Setting Value 0 5dBm Setting is valid after reset Fo...

Page 47: ...for more details 3 2 2 60 AT LPTIO Function nReady nLink WPS function mapping setting is valid after reset Format Query operation AT LPTIO CR ok status CR LF CR LF set operation AT LPTIO status CR ok CR LF CR LF parameter staus nReady nLink WPS function mapping off lpb100 default nReady nLink WPS function are mapping to HF LPC100 corresponding pin Pin44 Pin43 Pin15 on lpt100 nReady nLink WPS funct...

Page 48: ...ours Recommend to oven bake with N2 supplied Recommend end to reflow oven with N2 supplied Baked required with 24 hours at 125 5 before rework process for two modules one is new module and two is board with module Recommend to store at 10 RH with vacuum packing If SMT process needs twice reflow 1 Top side SMT and reflow 2 Bottom side SMT and reflow Case 1 Wifi module mounted on top side Need to ba...

Page 49: ...anghai High Flying Electronics Technology Co Ltd www hi flying com 49 4 3 Shipping Information TAPE BOX SIZE 340 340 70 mm SIZE 340 340 350 mm inside Figure 15 Shipping information Note 1 tape 500pcs 1 box 5 tape 5 500pcs 2500pcs H i g h F l y i n g ...

Page 50: ...g Electronics Technology Co Ltd www hi flying com 50 APEENDIX A HARD REFERENCE DESIGN Detailed HF LPC100 Evluation Board design source files pls access High Flying web download page or contact with High Flying technical support people to acquire H i g h F l y i n g ...

Page 51: ... be changed if the module is reset B 1 Network Command B 1 1 GPIO channel OUT value function set module GPIO channel output temporary value valid after save and reset parameter channel GPIO channel number can be 11 12 15 18 20 23 GPIO pin number value GPIO channel value 1 high voltage 0 low voltage return data GPIO OK command succeed GPIO NOK command failed B 1 2 GPIO channel GET Function query GP...

Page 52: ...IO channel number can be 11 12 15 18 20 23 GPIO pin umber return data GPIO OK command succeed GPIO NOK command failed B 1 4 PWM channel frequency duty Function set PWM channel output channel temporary value valid after save and reset Parameter channel PWM channel number can be 11 12 18 20 GPIO pin number frequency PWM frequency value 500 60000 duty PWM duty 0 100 return data PWM OK command succeed...

Page 53: ...y Co Ltd www hi flying com 53 B 1 5 PWM channel GET Function query PWM channel output value Parameter channel PWM channel number can be11 12 18 20 GPIO pin number return data ok frequency duty frequency PWM channel frequency duty PWM channel duty PWM NOK command failed H i g h F l y i n g ...

Page 54: ...Hexadecimal Network Command Send hexadecimal data to quickly read module s I O status send area and receive area must send and receive based on hexadecimal B 2 1 Read all GPIO channel Send data 0a return data 8a value value bit0 bit1represent GPIO15 GPIO23 value B 2 2 Reverse GPIO Channel value Send Data 03 channel channel GPIO Channel number it can be 01 02 GPIO15 GPIO23 Return Data 83 channel va...

Page 55: ... frequency value6 Low byte of PWM Channel 2 GPIO18 frequency value7 High byte of PWM Channel 3 GPIO20 frequency value8 Low byte of PWM Channel 3 GPIO20 frequency B 2 4 Write PWM Channel Frequency Send Data 32 channel value1 value2 channel PWM Channel number value1 High byte of PWM Channel frequency value2 Low byte of PWM Channel frequency Return Data b2 channel value1 value2 Channel PWM Channel nu...

Page 56: ...end Data 22 channel value1 channel PWM Channel number value1 Duty of PWM Channel Return Data a2 channel value1 Channel PWM Channel number value1 Duty of PWM Channel B 2 8 Save Present GPIO PWM Setting Send Data 7a Return Data fa B 2 9 Assert All GPIO Channel Low Send Data 04 Return Data 84 00 B 2 10 Assert All GPIO Channel High Send Data 05 Return Data 85 01 B 2 11 Read Resources of module Send Da...

Page 57: ...IP address and Port Number Format Query Operation AT HTTPURL CR ok IP Port CR LF CR LF Set Operation AT HTTPURL IP Port CR ok CR LF CR LF Parameters IP IP address Port Port number C 1 2 AT HTTPTP Function Set Query HTTP request type Format Query Operation AT HTTPTP CR ok Type CR LF CR LF Set Operation AT HTTPTP Type CR ok CR LF CR LF Parameters Type GET default or POST C 1 3 AT HTTPPH Function Set...

Page 58: ...der Format Query Operation AT HTTPUA CR ok Parameter CR LF CR LF Set Operation AT HTTPUA Parameter CR ok CR LF CR LF Parameters Parameter Max length is 20 bytes C 1 6 AT HTTPDT Function Send HTTP request or data Format Set Operation AT HTTPDT Data CR ok CR LF CR LF Parameters Data HTTP request data send AT HTTPDT directly if no data to be sent C 2 HTTP Example HTTP parameter settings are as follow...

Page 59: ...e User Agent lwip1 3 2 Content Length 0 Host 192 168 0 127 8999 If send AT HTTPDT abcd the data packet will be sent as the following instance POST abcd HTTP 1 1 Connection keep alive User Agent lwip1 3 2 Content Length 4 Host 192 168 0 127 8999 abcd The data received from HTTP server will be output to serial port and end with ok If the module hasn t received data from HTTP server for 5 second it w...

Page 60: ...ww pgyer com bNwD Android APP download address http www pgyer com 5zg5 Step 1 after installation user can find below icon shows on smart terminal Step 2 press nReload on LPC100 module to start Bluetooth one key configuration After module restart the nLink led twinkle slowly indicate that the Bluetooth is opened Step 3 mobile connect to router and open Bluetooth then connect to module Bluetooth H i...

Page 61: ...td www hi flying com 61 Note module s default Bluetooth name is BTFFFF BT last four byte of MAC address user can revise MAC address via AT BTMAC 8888 XXXXXXXXXXXX Step 4 click APP icon and enter the main page SSID the mobile connected router s SSDI Password router s password H i g h F l y i n g ...

Page 62: ...TA module to connect router nLink light stays on indicate the module already connected to router if configure failed nLink is off require configure again Note 1 after Bluetooth configure finished APP will continue sending configuration information in sonic way 2 if require configure again for the IOS device already connected via Bluetooth require connect again user must 忽略此设备 ignore this device an...

Page 63: ...r Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 63 3 High Flying Wi Fi module recommended hardware connection nReload press this button when use smart configure nLink link status indicator H i g h F l y i n g ...

Page 64: ...HF LPC100 Wi Fi Bluetooth Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 64 APPENDIX E HF LPX SERIES MODULE PIN COMPATIBLE TABLE H i g h F l y i n g ...

Page 65: ...lying com en END Copyright High Flying May 2011 The information disclosed herein is proprietary to High Flying and is not to be used by or disclosed to unauthorized persons without the written consent of High Flying The recipient of this document shall respect the security status of the information The master of this document is stored on an electronic database and is write protected and may be al...

Reviews: