Trackspot User Manual
Installing Remote Enable/Disable
2-7
2
SPST Switch
Note:
Connect only the master fixture to the SPST switch.
To install an SPST switch:
1. Unplug the fixture.
2. Locate the female Analog In connector on the rear panel of the
master Trackspot fixture (see Figure 2-2).
3. Connect DIN pin 1 and pin 5 together (see Figure 2-2). You can
connect these pins either at the fixture or in the male 8-pin DIN
connector.
4. Connect DIN pin 1 and pin 3 to the SPST switch (see Figure 2-2).
When correctly connected to the SPST switch, the fixtures will be
enabled when the circuit is closed and disabled when the circuit is
open.
External Voltage Source
Note: Connect only the master fixture to the external voltage
source.
To install an external voltage source:
1. Unplug the fixture.
2. Locate the Analog In female connector on the rear panel of the
master Trackspot fixture (see Figure 2-2).
3. Connect analog DIN pin 1 and pin 5 together (see Figure 2-2). You
can connect these pins either at the fixture end or in the male 8-pin
DIN connector.
Figure 2-2. Connecting a remote enable/disable switch to
the master fixture
remote SPST switch
OFF ON
Analog In Connector
1
3
5
6
7
4
2
8
FIXT URE MODE SWITCHES 1-2
NORMAL RUN
SELF TEST
SET-UP
NONE
1
2
1,2
LIGHTWAVE CONTROL
DMX 1-256
DMX 257-512
ANALOG
AUDIO (SLAVE)
AUDIO (MASTER)
PAN INVERT
TILT INVERT
NONE
5
4
4,5
3
6
7
AUDIO
M IC
PE RSONALITY
ADDRES S
ENABLE
FAN
ANALOG IN
DATA OUT
DATA IN
2209 WEST BRAKER L ANE, A UST IN, T EX AS U.S.A.
LIGHTWAVE RESEARCH
CONTROL MODE SWITCHES 3-8
8
PERSONALITY
SWITCHES
ON
PLEASE CONSULT USER MANUAL
FOR FURTHER INFORMATION
LAMP SAVE
PLEASE CONSULT USER MANUAL
FOR FURTHER INFORMATION
ON
SWITCHES
ON
SWITCHES
ADDRESS
ADDRESS
1,2,3,5
24
2,3,5
23
1,3,5
22
3,5
21
1,2,5
20
2,5
19
1,5
18
5
17
1,2,3,4
16
2,3,4
15
1,3,4
14
3,4
13
1,2,4
12
2,4
11
1,4
10
4
09
1,2,3
08
2,3
07
1,3
06
3
05
1,2
04
2
03
1
02
none
01
FUSE
VO LT AG E SELECT
WARNING: CHANGE VOLTAGE SELECT ONLY WITH POWER REMOVED.
CAU TION : HO T R EMO VE POW ER BEFO RE R ELAM P ING
WARNING: NOT FOR RESIDENTIAL USE. TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR MOISTURE,
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL. FOR SAFE OPERATION CONSULT
USER MANUAL.
(UNREG.)
OUT
INPUT
SPECIAL ANALOG
CONSULT USERS MANUAL
FOR FUTHER INFORMATION
24 VDC
SHUTTER
MSPEED
TILT
GOBO
DIM
PAN
COLOR
8
2
4
1
6
7
3
5
GND
5
3
7
6
1
4 2
8
ANALOG
0-10V
GND
trackspot
14
0
20
0
120
240
10
0
22
0
MODEL
SERIAL
FACTORY SET VAC
WATTS HZ
DATE QC