Configure the Fixture
15
Set Fixture Parameters
This section provides instructions to configure and set up the SolaFrame 3000. See
Navigate the
User Interface on the previous page
for information on the navigation buttons.
Provide power to the fixture before configuring it. If you do not provide power, the fixture will
use battery power to power the user interface.
DMX Address
Navig ate: Main Menu
→
Address
Set the DMX address for the fixture. The default value is 001.
Info Menu
Set the Time Information
Navig ate: Main Menu
→
Info
→
Time Info
Parameter
Value
Description
Current Time
XXXX (Hours)
Running time of the fixture from the last time that
the fixture was powered on, shown in hours (h). The
counter resets after the fixture is turned off.
Ttl Life Hrs
XXXX (Hours)
Total running time of the device, shown in hours (h).
Last Run Hrs
XXXX (Hours)
Running time of the fixture from the last time that
the fixture was powered on, shown in hours (h).
LED Hours
XXXX (Hours)
Total running time of the fixture LEDs, shown in
hours (h).
Timer PIN
Password = XXX
Enter the Timer PIN. The default Timer PIN is 038.
You must enter the Timer PIN in order to access the
Clr Last Run parameter.
Clr Last Run
•
ON
•
OFF
You must enter the Timer PIN to access this para-
meter. Select ON to clear the value for the Current
Time parameter for the fixture.
LED Time PIN
Password = XXX
Enter the LED Time PIN. The default LED Time PIN is
038. You must enter the LED Time PIN in order to
access the Clear LED Time parameter.
Clear LED Time
•
ON
•
OFF
Please contact technical support at High End
Systems, Inc. before using this parameter to clear
the LED Hours value. See
Contacting High End
Systems on page 1
.
You must enter the LED Time Pin to access this
parameter.
Select ON to clear the value for the LED Hours
parameter.