CHAPTER 5
DMX Programming
SHAPESHIFTER User Manual
43
Control
The
Control
parameter allows remote control of Display, Homing, Module Lamp and Shutdown.
Note:
To access all control settings, first select a control channel value, then
set the Shutter channel to DMX = 0.
Control Setting
DMX
Value
Description
Safe
0-5
Disables all Control settings for normal operation
Pan and Tilt MSpeed Off
16-31
Disables MSpeed
Display/LEDs Off
32-47
Turns display and all LED modules off
Display/LEDs Bright
48-63
Turns display and all LED modules fully on
Home All
64-79
Remotely homes all the fixture components
Shutdown
80-95
Remotely shuts down the fixture. When a fixture is shut down, the LEDs
are off and power to the motors is disabled. If a fixture is in shutdown
mode, the fixture must be homed to bring it back into operation.
Module X Invert On
112-127 This menu option inverts the direction of the Module X motor operation to
coordinate movements between SHAPESHIFTER fixtures mounted
opposite each other horizontally.
Module X Invert Off
128-143
Module Y Invert On
144-159 This menu option inverts the direction of the Module Y motor operation to
coordinate movements between SHAPESHIFTER fixtures mounted
opposite each other vertically.
Module Y Invert Off
160-175
Module XY Swap On
175-191 These options swap the Module X and Y motor operation to coordinate
movements between SHAPESHIFTER fixtures mounted perpendicular to
each other
Module XY Swap Off
192-207