background image

3

ZRX500.2 / ZRX1200.2 2-CHANNEL AMPLIFIER APPLICATIONS 

4. Line Level:

This is the most basic application for the ZRX Series 2 channel amplifiers.

Refer to the section 

“Setting up systems after installation for best performance”

1. Interconnect cable checklist:

Connect the 

LINE INPUTS

 to the Radio/CD  with good quality RCA cables.

NOTE: Minimum final loudspeaker impedances:

2. Crossover Switch:

4 & 2 Ohms stereo mode or 4-Ohms mono mode

The 

X-OVER

 switch must be in the 

FULL 

position.

This amplifier will not do 1 Ohm stereo or 2/1 Ohm mono operation.

3. Crossover frequency control checklist:

N/A for full range operation.

FULL RANGE STEREO

MONO

Switch setting checklist:

This  application  illustrates  the  basic  mono  bridging  method  for  all  Hifonics 

- The 

AMPLIFIER X-OVER

 switch should be in the 

LP/BP

 position.

amplifiers.

Crossover frequency control setting checklist:

Interconnect cable checklist:

LPF: 11 o’clock

A MONO signal source is required, such as would be available from the mono 
sub bass output of an active crossover, whether stand alone, or built into a head 

Minimum final loudspeaker impedance:

unit or equalizer. 

Important:

 Do not be tempted to connect the hot, or positive 

outputs, from any source together to obtain a mono signal, as this could very 

- 4 ohm mono.

well damage the output stage of that source.
It is necessary to feed the SAME signal to both left and right inputs via a Y-
adapter RCA cable. Connect the mono speaker positive terminal to the LEFT +, 
and its negative terminal to RIGHT -.

ZEUS

PO

WER

LEVEL

          BASS EQ    X-OVER          HPF                LPF             MODE

PROTECT

OUTPUT

INPUT

L

R

L

R

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FULL

MONO

HPF

STEREO

LPF

POWER INPUT

GND      REM   BA

TT+12V

SPEAKER OUTPUT

RIGHT                      LEFT

-          +          -          +

BRIDGED

FUSE

ZEUS

POWER

LEVEL

          BASS EQ    X-OVER    

      HPF                LPF   

          MODE

PROTECT

OUTPUT

INPUT

L

R

L

R

6V      0.2V     0dB   12dB                    60HZ  13KHZ  30HZ  250HZ

FULL

MONO

HPF

STEREO

LPF

POWER INPUT

GND      REM   BA

TT+12V

SPEAKER OUTPUT

RIGHT                      LEFT

-          +          -          +

BRIDGED

FUSE

REMOTE TURN-ON

CHASSIS GROUND

TO B12v
       VIA FUSE

FULL RANGE

SPEAKERS

FULL RANGE

STEREO LINE INPUT

FULL RANGE

MONO LINE INPUT

VIA Y-ADAPTER

FROM MONO SOURCE

REMOTE TURN-ON

CHASSIS GROUND

TO B12v
       VIA FUSE

MONO SPEAKER

or SUBWOOFER

Summary of Contents for Zeus ZRX1000.4

Page 1: ...ZRX500 2 ZRX1200 2 ZRX600 4 ZRX1000 4 ZRX2000 4 ZRX1200 1D ZRX1800 1D ZRX2400 1D ZRX3200 1D...

Page 2: ...with out the written consent of MAXXSONICS USA Inc ZEUS HIGH PERFORMANCE AMPLIFIERS The Zeus ZRX Series products have been designed to a very high level of performance with features unavailable in any...

Page 3: ...learance hole in the chassis the same size as the lug hole and use a bolt spring washer and nut to securely fasten the ground lug Use petroleum jelly to coat the bolt lug connection to prevent oxidiza...

Page 4: ...multipleamplifiersfromonesignal Note that the LOW PASS signal is MONO In the LPF position the HIGH PASS filter acts as a subsonic filter When the LPF mode is selected a 0 to 12dB at 45Hz BASS EQ is al...

Page 5: ...ver whether stand alone or built into a head Minimumfinalloudspeakerimpedance unit or equalizer Important Do not be tempted to connect the hot or positive outputs from any source together to obtain a...

Page 6: ...standalone or built into a head unit or equalizer If you only have 1 set of RCA outputs from your headunit you can simply connect those to the inputs for ch TIP If you are using the mono sub bass out...

Page 7: ...klist afterinstallationforbestperformance 4channelhighsamplifier 1 2CHX OVER HPF Levelcontrolchecklist 3 4CHX OVER HPF Refertothesection Settingupsystemsafterinstallationforbestperformance 2channelbas...

Page 8: ...Theseampsaremono 1channel amplifiers Minimumfinalloudspeakerimpedance 1 Ohm which have multiple positive and negative connections for ease of wiring The 2 positives arethesameinternallyandthe2negativ...

Page 9: ...7...

Page 10: ...ss to 100Hz the amplifier will not play frequencies below 100Hz but will play frequencies from 100Hz to the highest frequency the amplifier is capable of reproducing When in Low Pass Bandpass operatio...

Page 11: ...undandremoteleadsconnected theamplifiermaybefaulty Systemdoesnotturnon 1 Checkallfuses 2 Checkallconnections 3 Measure the 12 volt and remote turn on voltages at the amplifier terminals If these are n...

Page 12: ...in the name and address of the authorized reseller Any damage to the product as a result of misuse abuse accident incorrect wiring improper installation alteration of date code or bar code labels revo...

Page 13: ...11 Biggest POWER systems Moderate POWER systems Smaller POWER systems V3 Products Level 10 Performance 1 Year Warranty V1 Products Level 5 Performance V2 Products Level 7 Performance 6 Month Warranty...

Page 14: ...PART A113...

Reviews: