MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
• Before starting the installation, fully read through this manual and have the tools and
materials you are going to need to do so at hand.
• Water softeners should be installed and connected to inlet, outlet and drainage pipes
according to the producer’s instructions and complying with the current regulations
regarding low voltage electrical installations and hydraulic installations.
When unpacking, we have to bear in mind the following:
• That the system is in perfect condition and hasn’t received any knocks during transportation.
• Do not turn the package upside down or place it on irregular or sharp surfaces.
• That the accessories included are the correct ones and the ones necessary.
5.1.- Unpacking
1
It must have the relevant protection systems according to RBT (low voltage regulation) but not be interrupted by any switch or have
motors connected to the same line.
2
As close as possible to the equipment and at least 30 cm below an overflow outlet. For other types of installations, consult the technical
office first.
3.- INSTALLATION REQUIREMENTS
4.- SAFETY MEASURES
5.- INSTALLATION & CONNECTIONS
•
Installation must be carried out by a qualified technician.
•
Make sure the main water supply is turned off before starting the installation.
•
Always install an original and/or external bypass system.
•
An uninterruptible power outlet is necessary
1
230V
ac
- 50Hz and a drain near
2
the system.
•
After finishing the installation and when starting up, check and repair any leaks if necessary.
Choosing the location of instalment
• The adequate place where you choose to put the system must have easy access to access
the system and also to fill up the salt tank.
•
The system must be placed on a flat surface, protected from direct sunlight, rain and humidity.
•
The system (including the overflow and drainage lines) must be placed out of freezing
temperatures and those that are over 43ºC.
• The system mustn’t be installed near acid nor vapours, or be exposed to products derived
from petroleum, to avoid the risks of deflagration and explosion.
• Do not install any unit between the outlet of the softener and the inlet of the water heater within
less than 3m of piping. If there is a heating element in the system, a non-return valve must be
installed to prevent the hot water damaging the water softener.
2.6.- Dimensions
2.7.- Characteristics
•
Automatic compact softeners to remove hardness via interchangeable ionic resins.
• Low water and salt consumption.
•
Volumetric CLACK WS1CI UF valve, digital programmer and delayed or instant counter-flow
regeneration
• Housing cabinet made of polythene.
•
Bottle tank made of wound Polythene with glass-fibre reinforced polyester (GFRP).
• Regeneration through consumption.
• Programmable forced regeneration frequency.
• Integrated hardness mixer.
• Turbine to control the volume of treated water.
• 1” connection.
• Bypass option and 1” 90º elbow joint adapter.
• Security salt buoy included.
• Resin loading for food use, high capacity for high performance
• Voltage: 230V-15V DC 50Hz.
Code
System
Packaging
Dimensions (mm)
Weight
(Kg)
Dimensions (mm)
Logístics (Units)
A
B
C
A
B
C
Pallet
20ft
Cont.
40ft
Cont.
UF-3004-02 = UF-3004-07
351 523
705
24
370 540
760
5
90
220
UF-3004-04 = UF-3004-08
351 523
1134
33
370 540 1160
5
45
110
UF-3004-05 = UF-3004-09
351 523
1134
45
370 540 1160
5
45
110
Code
Model
Work flow (m
3
/h)
Salt consumption
(Kg/reg.)
By-pass
UF-3004-02
CRV 14L
0,5
1,4
NO
UF-3004-04
CRV 22L
0,7
2,2
NO
UF-3004-05
CRV 35L
1,2
3,5
NO
UF-3004-07
CRV 14L
0,5
1,4
YES
UF-3004-08
CRV 22L
0,7
2,2
YES
UF-3004-09
CRV 35L
1,2
3,5
YES