Hidro-Water ATHENEA Manual Download Page 2

 

ref: MA-UF-0002-EN-V14.0-ATHENEA.pdf 

 
1.- INTRODUCTION 
 
 

This  manual  explains  the  installation  and  operation  of  equipment  made  by  HI-

DRO-WATER, S.L. for water treatment by ultrafiltration for household use. The equip-
ment has been designed to be connected to the housing facility. 
 

It  is  easy  installation  and  operation  as  it  has  already  been  semi-assembled.  It 

requires very little assembly as it is only necessary to connect the hydraulics and install 
the faucet as indicated in point 4 of this manual.  
 

In the absence of installation and maintenance as described in this manu-

al by technically qualified personnel to ensure the quality of water produced and 
proper installation, the warranty is void. 
 
 

2.- PRECAUCIONES Y ADVERTENCIAS 

  

 

Please read this manual carefully following the warnings listed below before going 

ahead with the installation and use of the ATHENEA ultrafiltration system. If you have 
any doubts, please contact an official HIDRO-WATER S.L distributer.  

 

  For the correct operation of osmosis systems with a pump, the pressure should 

be between 2.5 and 4 bars. 
 

  The temperature of the water to be treated should not be below 4ºC nor above 

40ºC to avoid damaging the system. 

 

   The ultrafiltration system is designed to treat tap water with a maximum salinity 

of 1500 ppm. Do not use in places where the water is not microbiologically safe 
or  has  an  unknown quality.  For  water  with  a greater  salinity  level,  please  con-
tact an official HIDRO-WATER S.L distributer.  

 

  It  is  advisable  that  the  water  to  be  treated  has  been  softened  or  with  a  maxi-

mum hardness of 15ºHF for optimum performance.  

 

  If the water has a high concentration of iron or magnesium, nitrate concentration 

greater  than  100  ppm,  sulphate  concentrations  greater  than  250  ppm,  more 
than  3  NTU  turbidity  and/or  prolonged  use  of  high  chlorine  levels,  please  con-
tact  an  official  HIDRO-WATER  S.L  distributer  to  suggest  an  appropriate  pre-
treatment system to ensure the correct operation of the system. 

 

  If the osmosis system is not going to be used for a long period of time, close the 

water passage.  

 

  Install the system on a flat surface. 

 

  Do not expose the system to direct sunlight or install it outdoors.  

 

  The installation should be done by professionally qualified personnel and should 

not be installed close to a heat source.  

 

  Do not repair or take the system apart on your own. If the system is not working 

correctly,  please  contact  an  official  HIDRO-WATER  S.L  distributer.  Any  tam-

Summary of Contents for ATHENEA

Page 1: ...tion 5 4 3 Ultrafiltration instllation 5 5 ULTRAFILTRATION SYSTEM START UP 7 6 INSTRUCTIONS AND MAINTENANCE 8 6 1 Procedure for replacing cartridges and the membrane 9 6 2 Procedure for replacing the WATER STOP anyileak absorbent material 10 7 FAULTS PROBABLE CAUSES AND POSSIBLE SOLUTIONS 11 8 SPARE PARTS 14 9 MONITORING AND MAINTENANCE CONTROL 12 9 1 Ultrafiltration spare parts 12 ...

Page 2: ... not be below 4ºC nor above 40ºC to avoid damaging the system The ultrafiltration system is designed to treat tap water with a maximum salinity of 1500 ppm Do not use in places where the water is not microbiologically safe or has an unknown quality For water with a greater salinity level please con tact an official HIDRO WATER S L distributer It is advisable that the water to be treated has been s...

Page 3: ...ormance of the system For installation maintenance and cartridge change please follow this manual otherwise the warranty will be void 3 CHECKING THE CONTENTS Open the packaging and make sure that all of the components are inside ready for the installation Figure Description 1 ATHENEA ultrafiltration system main unit 2 New Look Faucet 3 PE Tube 4 Feed adapter 5 M x T ball valve 6 plastic insert 7 f...

Page 4: ...nd sufficient space to be located The most common place is under the kitchen sink The installation should be carried out by qualified per sonnel onnel 4 1 Faucet installation Figure 2 a Choose the location on the counter where you want to install the faucet b Use a drill with a 12mm bit to make a necessary sized hole to put the faucet c Fit the tap in the hole as indicated in the fig ure using a s...

Page 5: ...l trafiltration system will be damaged Make sure that the brass ball valve is closed 4 3 Ultrafiltration system installation The hydraulic connections should follow the contour of the surface cho sen for installation so that the tubes do not get mixed up or tangled Leave a suf ficient length of tube to ease moving the system during future maintenance Here are the steps to follow to make the hydrau...

Page 6: ...ration system Figure 1 where it s marked IN inserting it fully Once inserted place the security clip on it e Screw the faucet adapter figure 7 to the faucet plac ing the supplied O Ring between the adapter and the stud Insert tube through this adapter s nut and sleeve then insert a plastic insert Figure 6 in that end on the tube Then you must insert that end in the faucet s adapt er and tighten th...

Page 7: ...ater leak If there is close the valve and fix it e Open the faucet Figure 2 and let all of the air out from inside the ultra filtration system Once a continual water flow comes out of the faucet let it run for 30 seconds and then close the faucet If in the beginning the water runs black don t worry this is normal it s caused by the resi due that the granulated carbon filter lets off Drain this wat...

Page 8: ... and the correct operation of the osmosis system the war ranty will be void Cartridge type Antibacterial Sediments cartridge Carbon CTO cartridge Ultrafiltration membrane Nanosilver Carbon cartridge Stage 1st 2nd 3rd 4th Reference CA 0218 03 CA 0218 05 CA 0218 04 ME 0218 06 Appearance Replace 6 9 month 6 9 months 1 2 years 6 9 months Sanitation Every time you change a cartridge the membrane or a c...

Page 9: ...se and pulled downwards to remove it from its cap as indicated in the follow ing figure This process must be carried out for each of the cartridges that you want to replace d Remove the cartridges membrane from their original packaging Each car tridge and or membrane must be placed in the correspond ing position main taining the correct order To do so you must insert each cartridge in its cap and ...

Page 10: ...e are any close the valves and fix them Precaution 1 If there is any water leak in any area of the tube connections re move it and cut off 0 5cm Then reconnect it If the leak s produced on any thread unscrew the piece apply more Teflon and screw it back on 6 2 Procedure for replacing the WATER STOP antileak absorbent material In the case of having to change the WATER STOP Antileak absorbent materi...

Page 11: ...t valve fully c Replace cartridges d Replace membrane e Check if the Antileak system has been activated If so find the leak and fix it change the absorbent material and lower the arm on the Antileak system 2 Plastic or synthetic taste a Worn Nanosilver Carbon cartridge a Replace cartridge 3 Chlorine taste and smell a Worn cartridges a Change the cartridges 4 Unpleasant taste and smell a Contaminat...

Page 12: ...ew Look faucet 1 8 OI 0207 54 plastic insert 2 9 TU 0602 01 Tube 1 10 ATHENEA Ultrafiltration system support bracket 1 11 OI 0235 02 QC3 cartridge cups 4 12 OI 0208 16 M x T Straight 2 13 OI 0208 04 M x M Double Male connector 3 14 CA 0218 03 QC3 Antibacterial sediments cartridge 1 15 CA 0218 05 QC3 Carbon Block CTO cartridge 1 16 ME 0218 04 Ultrafiltration membrane 1 17 CA 0218 06 QC3 NANOSILVER ...

Page 13: ...ref MA UF 0002 EN V14 0 ATHENEA pdf 13 1 2 3 5 4 6 7 8 9 10 11 12 11 11 11 13 14 15 16 17 18 19 20 21 22 ...

Page 14: ...CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CT...

Page 15: ...mbrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Memb...

Page 16: ...ref MA UF 0002 EN V14 0 ATHENEA pdf 16 ...

Reviews: