Input 

Number 

V2000 

V1000 

V100 

V200 

V300 

P7 Pins 8/7 

Tamper 

P7 Pins 4/3 

Batt Fail 

P7 Pins 8/7 

Tamper 

P1 Pins 9/10  

P7 Pins 4/3 

Batt Fail 

P7 Pins 6/5 

AC Fail 

 

P7 Pins 6/5 

AC Fail 

P2 Pins 1/2 

 

P7 Pins 4/3 

Batt Fail 

 

P7 Pins 4/3 

Batt Fail 

P2 Pins 3/4 

 

   

P2 

Pins 

5/6 

 

   

P4 

Pins 

10/9 

 

10 

   

P4 

Pins 

8/7 

 

11 

   

P4 

Pins 

6/5 

 

12 

   

P4 

Pins 

4/3 

 

13 

   

P4 

Pins 

2/1 

 

14 

   

P5 

Pins 

6/5 

 

15 

   

P5 

Pins 

4/3 

 

16 

   

P5 

Pins 

2/1 

 

17 

   

P7 Pins 8/7 

Tamper 

 

18 

   

P7 Pins 6/5 

AC Fail 

 

19 

   

P7 Pins 4/3 

Batt Fail 

 

 

Contact Information 

HID Corporation 

929274 Jeronimo Road, Irvine, CA 92618-1905 

Web Site 

http://www.hidcorp.com

 

Main Phone  (949) 598-1600 

Fax (949) 

598-1698 

 

 

Sales (800) 

210-4744 

Technical Support  (800) 237-7769 

Summary of Contents for Vertx CS V100

Page 1: ...proprietary information which may not be duplicated published or disclosed to others or used for any purpose without written permission from HID Corporation 2004 HID Corporation All rights reserved Do...

Page 2: ...TART VERTX CS V100 Door Reader Interface Panel 1 Introduction 3 Parts List included 3 Product Specifications 3 Cable Specifications 3 Overview 4 Step 1 Preparations 4 1 1 What you need before getting...

Page 3: ...ic or Mylar cover 1 Mounting screws 4 2 2K EOL resistors 4 Quick Installation Guide 1 Installation Wiring Diagram Example 1 Note A VertX V1000 Access Controller is required Product Specifications Desc...

Page 4: ...read through this guide CAUTION The V100 is sensitive to Electrostatic Discharges ESD Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precau...

Page 5: ...ir flow and cable runs 2 2 Wiring VertX 1 Power and Alarm input connections Connect power by providing 12VDC to the P7 connector 12VDC goes to Pin 1 and Ground on Pin 2 The Bat Fail AC Fail and Tamper...

Page 6: ...re Installation Worksheet found in the back of the HID VertX V1000 Quick Install guide 5 Output Connections All Output connections are used for general purpose controls The following table shows where...

Page 7: ...lly Closed NC unsupervised no EOL resistors All other input points are defaulted for NO switches and are unsupervised no EOL resistors Any input can be configured as a supervised input They can be con...

Page 8: ...Fail P2 Pins 1 2 7 P7 Pins 4 3 Batt Fail P7 Pins 4 3 Batt Fail P2 Pins 3 4 8 P2 Pins 5 6 9 P4 Pins 10 9 10 P4 Pins 8 7 11 P4 Pins 6 5 12 P4 Pins 4 3 13 P4 Pins 2 1 14 P5 Pins 6 5 15 P5 Pins 4 3 16 P5...

Page 9: ...h case the user will be required to correct the interference at his own expense Class B Digital Devices FCC Compliance Statement This equipment has been tested and found to comply with the limits for...

Reviews: